11.0 MEV-SVS units

Nuaire's MEV-SVS units are designed to provide

continuous mechanical supply/extract ventilation to

homes enabling each room to be individually ventilated.

Coding:

MEV - SVS

Comprising a supply fan unit, an extract fan unit and a

unique multi-spigoted distribution box.

Attenuators to be specified and supplied seperately.

MEV-SVS control wiring using remote speed

control (Opus-SPD)

The extract fan operates continuously in trickle mode.

The supply fan will operate in trickle mode when

activated by the supply fan switch.

The remote boost switch will set both extract and

supply fans to boost if they are operating in trickle

mode. If the supply fan is switched off, only the

extract fan will operate.

Supply fan boost airflow should be set to fully

clockwise.

The supply fan will only operate on boost speed from

the boost switch if the speed control is set to off.

Extract fan airflows should be set to meet Part F

requirements.

Installation and Maintenance

MEV-SVS

Continuous Mechanical Ventilation Supply/Extract Units

6

Leaflet Number 671266 July 2007

Figure 9. Typical installation.

Fresh filtered air

into habitable rooms

1

2

3

4

1

2

3

4

4

4

12.0 Electrical Wiring (MEV-SVS)

Figure 10.

Supply

230V

50Hz

1 Ph

N

L

SL

N

L

Extract 

Fan

3 Pole
isolator

Boost switch

N

L

SL

Supply

Fan

3 Pole
isolator

T

V

L

To remote 
speed 
control

M

3A

Supply fan 

switch

S

Supply Unit

Extract Unit

Supply Air Distribution Box

Extract Points “Wet Rooms”

Figure 11.

MEV-SVS wiring using light/remote switches

The extract fan operates continuously in trickle mode.

The supply fan will operate in trickle mode when

activated by the supply fan switch.

The remote boost switch will set both extract and

supply fans to boost if they are operating in trickle

mode. If the supply fan is switched off, only the

extract fan will operate.

Supply fan boost airflow should be set to fully

clockwise.

Extract fan airflows should be set to meet Part F

requirements.

3A

Room 
light

N

L

SL

N

L

3 Pole
isolator

Extract fan 
boost switch

M

N

L

SL

Supply

Fan

3 Pole
isolator

Extract 

Fan

Supply

230V

50Hz

1 Ph

Light
switch

All switches by others

3

Supply fan 

switch

For good EMC engineering practice, any sensor cables

or switched live cables should not be

placed within 50mm of other cables or on the same

metal cable tray as other cables.