Leaflet Number 671266 July 2007

The spigot locations are as follows:

Two x 125mm inlet end spigots.

Two x 100mm inlet spigots on LH side of case.

Two x 100mm inlet spigots on RH side of case.

One x 125mm discharge end spigots.

Any, or all of these inlets can be utilised with individual

volume control being available via the relevant damper.

A filter frame with a replaceable filter is ‘push fit’ located

inside the case which is easily removed for cleaning

following removal of the case cover.

Please note a clear space of at least 470 x 320mm is

required to allow the cover to be removed and provide

sufficient access for maintenance.

The fan is designed to be wired direct to the mains supply

through a fused spur isolator (by others) and run

continuously in the NORMAL mode (which is the low speed,

background or trickle ventilation setting) with occasional

BOOST airflow (high speed setting) as and when required.

The degree of extract from each room served can be

adjusted with the inlet balancing spigots.

The unit is provided with adjustment for the low speed

(NORMAL) and high speed (BOOST) ventilation rate

as required.

2.2 Electrical connection

With the unit fixed in position and working from underneath

the installation bring the external wiring through the chosen

rubber cable entry grommet (two either side, see figure 2).

The unit MUST be Earthed.

Installation and Maintenance

MEV Ecosmart Continuous Mechanical Extract Ventilation Units

470

3

4

0

12

5

d

ia

17

0

Bracket 

fixing

VIEW WITH COVER REMOVED

SIDE  VIEW

Cable entry 20mm

MOUNTING BRACKET TOP VIEW

Mounting bracket

END  VIEW

Single screw unit fixing

18

6

10

140

4 holes 

7.5 dia.

4 x Spigot

knockouts

100 dia.

1 x Spigot

knockout

125 dia.

50

2 x Spigot

knockouts

125 dia.

3.0 Dimensions

Figure 5. Dimensions in mm.

Isolation - Before commencing work make sure

that the unit, and Nuaire control are

electrically isolated from the mains supply.