NuAire CYFAN-C Installation And Maintenance Manual Download Page 9

CYFAN-C EXTRACT FANS 

INSTALLATION AND MAINTENANCE

9

10. 05. 17. Leaflet Number 691500

SECTION 3.0 
FITTING THE PRODUCT
WINDOW MOUNTING

3.11 Fitting the window kit cont.

3.

Back draught Shutters (see fig 2 and fig 19. are clipped into Inner
clamp and the spring is fitted in the lower position.

4.

Position the assembly on the outside of the glass. If only one
person is installing the fan it may be helpful to tape the assembly
to the outside glass at this stage during installation as all fixings
and assembly are completed from inside. 

5.

Working from inside the room with the clamp. Position this inner
clamp over the hole in the glass and and line up the 4 mounting
holes.

6.

Select appropriate screws from the screws kit supplied for
mounting into different thicknesses of glass, see table below.
Should the screws foul on the back of the grille during
installation replace with the next size down. There are 2 long and
2 short screws for each thickness of glass, the shorter screws are
at the top.

7.

Using four screws locate with the screw bosses in the outer
assembly, draw the inner and outer assemblies together. 
Remove any tape supporting the outer assembly and continue to
draw the units together until the ‘O’ ring is compressed on the
window. Note: do not over tighten the fixing screws as this may 
distort the assembly. 

8.

Wire unit in accordance with the appropriate wiring diagram. 
A cable clamp is provided inside the case. Note: the remaining
installation procedures for Window Mounting are as the
description in section 3.10.

Window mounting Screws

Window thickness 

Screw size

2 off

4mm - 11mm

No8 x1” CSK HD

2 off

No8 x1-1/2” CSK HD

2 off

12mm - 21mm

No8 x1-1/2” CSK HD

2 off

No8 x1-3/4” CSK HD

2 off

22mm - 32mm

No8 x1-3/4” CSK HD

2 off

No8 x2-1/4” CSK HD

Fig 19. Spring assembly. (Also see fig 2).

Backdraught 
Shutter x 2

Spring

Inner Clamp

Window Cover and 
Outside Clamp Assembly  

Window Inside Clamp

Backdraught Shutter x 2

Spring

Fan Skirt and
Body Assembly

180394 Pan Head Screws x 4

Window Screw 
short x 2

Window 4mm to 32mm thick glass
cut 125mm dia. hole for fan

Cable entry

Window Screw long x 2

Fig 20. Window mounting using the optional window mounting kit. The window kit is designed for mounting the unit into windows

4mm to 32mm thick using a 125mm dia. hole in the glass.

Summary of Contents for CYFAN-C

Page 1: ...rate toilet Part number CYFAN DKIT n Semi recessed mounting kit Part number CYFAN RKIT n Optional filter available Part number 7702017 1 4 What comes in the box The following components are included S...

Page 2: ...o 24V conversion n All Wiring Diagrams Section 3 Fitting the Product Page 6 Section 4 Setting the Product to work Page 12 n Default settings n Part F Flow rates n Air flow adjustment Inc Controls labe...

Page 3: ...e simple steps to fit your back draught shutters if required It is advised to fit the shutters before installing the fan unit n Collect all required parts n 125mm shutters 2 off 41285 or 100mm shutter...

Page 4: ...osition the transformer base enclosure on mounting surface and route cables through knockouts Mark the fixing points on the mounting surface Secure using suitable fixings by others 3 Before fitting se...

Page 5: ...if not fitted fan will run at full speed only 24V 0 SL Fan unit Section 2 PCB Transformer Box Fan unit Section 2 PCB 2 Pole switch Fuse 2A BS 1362 N L Mains 230V 50Hz Wiring for two room installation...

Page 6: ...n spigot placed into core cut hole and use the base as a template to mark the mounting screw hole positions x3 remove casing once marks are made 8 Drill and plug if necessary the mounting surface 9 Fe...

Page 7: ...ed wiring flex through the back of the fan casing and mounting plate 11 Secure the case to the surface fixings supplied by others Note care must be taken not to twist or distort the case whilst fittin...

Page 8: ...replace PCB fully into position by pushing the dip switches 10 Replace PCB cover by fitting with 2 off No6 x 1 2 inch screws see point 2 of the procedure Fig 17 Use cable clamp on rear of casing to s...

Page 9: ...osses in the outer assembly draw the inner and outer assemblies together Remove any tape supporting the outer assembly and continue to draw the units together until the O ring is compressed on the win...

Page 10: ...lter f Reduction Filter Fig 22 Example of a subsidiary spigot kit Code CYFAN DKIT Note 50mm grille available Code 50IG 2 Place the front cover to one side 3 Place the reduction filter over the grille...

Page 11: ...tting 13 Partially replace PCB into the new fan casing and wire flex into the terminal block see wiring options on page 5 Go to point 19 14 Utilizing the fan skirt Using the template on page 12 mark o...

Page 12: ...K Relative Intermittent Intermittent Humidity Boost Set at 60l s Boost Set at 30l s 60 20 l s 10 l s 70 30 l s 15 l s 80 40 l s 20 l s 90 50 l s 25 l s 100 60 l s 30 l s Fan Failure Boost Humidity Fan...

Reviews: