5.0 ACCESS TO UNITS
5.1 HINGED OR REMOVABLE ACCESS PANELS
Figure 10: The unit must be installed with at least 600mm clearance from a wall / barrier to gain access from the side.
Isolate before removing panels.
In this product range, several unique concepts have been implemented with
a view to simplifying the installation design.
1. The unit must be installed with at least 600mm clearance from a wall/
barrier. With this absolute minimum clearance, the unit may be connected to
the power supply and control connection.
2. With this clearance, unit filters may be changed, and the fans coils, heat
exchanger and condensate tray may be inspected and cleaned if necessary.
3. The LPHW and Electrical heater settings, coil bleed and drain, and all other
control adjustments are similarly accessible.
4. Side access, where possible, is preferred in all cases in terms of safe working
access to the equipment under the CDM regulations.
5. Where these arrangements are not suitable, the Consultant’s and
Contractor’s project specific requirements will always be accommodated
where possible.
All hinged access panels will be lockable and removable via locked hinges which
can be opened for panel removal. All keys are identical and will open any handle
or hinge.
The hinges do not need to be unlocked in normal operation of opening and
closing.
Figure 11: All hinged access panels will be lockable and removable.
Easily removable
blowers for
maintenance
Access to built-in controls
Interchangeable filters
slide in and out
Hinged or removable
access panels
Access to
Plate Heat Exchanger
Access to interchangeable coils, LPHW
heater and chilled water cooling option
8mm outside diameter
condensate drain.
Condensate pump
fitted as standard
(where necessary).
Summary of Contents for BOXER B815H Series
Page 19: ...Figure 18...
Page 21: ...21 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 21 Figure 19...
Page 23: ...23 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 23 Figure 20...
Page 25: ...25 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 25 Figure 21...
Page 27: ...27 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 27 Figure 22...
Page 29: ...29 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 29 Figure 23...
Page 31: ...31 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 31 Figure 24...
Page 33: ...33 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 33 Figure 25...
Page 35: ...35 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 35 Figure 26...
Page 37: ...37 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 37 Figure 27...
Page 39: ...39 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 39 Figure 28...
Page 47: ...47 04 11 19 Leaflet Number 671827 BOXER BPS ECOSMART CLASSIC CONTROL ES 47 NOTES...