General 

 
The Thermatronic Control System is a battery operated gas fire control system that uses a microprocessor to provide 
the working sequences needed by the fire, and when used with an oxypilot has all the safety features required by law 
and CE approval. 
 
Commands are accepted by the microprocessor when buttons are pressed.  An audible beep means that the command 
is received, and the push button should immediately be released.  

 
 
Using The System 

 

Control can only be achieved if the transmitter is pointed at the fire. 
The red light will flash each time you press a button on the handset. 
 

A - Ignition

 

Simultaneously press and hold the red button and the right upper button (linked by line) 
until a short acoustic signal confirms that the sequence has begun, then release the 
buttons.  Continuous audible signals confirm that ignition is in progress.  When pilot 
ignition is confirmed the motor will open the valve to maximum flame height 

– this takes 

about 30 seconds. 
 

B - Flame Height Adjustment

   

Press the small flame button until the flame height is at the desired position.  If you try to 
go beyond the preset low flame minimum height the main burner will turn off leaving the 
pilot burner alight (this is the standby position).  You will learn from experience the preset 
low flame minimum height. 
 
To relight the fire from the standby position, or to increase the flame height from low 
flame, press and hold the large flame button until the desired flame height is achieved.  
Please note that you can have the flame height anywhere between maximum and preset 
low.  For fine adjustment simply tap the up or down arrows. 
 

C - To Switch Off 

Press the red/off button on the handset. 

 
D - General 

Battery replacement is recommended at the beginning of each heating season, or when an acoustic error message 
sounds during ignition. 
 
Error Message 

– Long signals (0.8 second tone – 0.2 second break) during ignition – probable cause - batteries in 

receiver are nearly discharged. 
 
Error Message 

– 5 second continuous tone – probable cause – cable disconnected or on/off switch on valve is in off 

position. 
 
 
Batteries 

Receiver Box - 4 x AA good quality alkaline 

 

 

 
Handset 

– 1 x PP3 good quality alkaline 

 

 

 

 

 
 

 
 
 
 
 
 
 
 