20.9 -

 

FUMES EMITTING FROM THE FIRE 

It is quite normal for fumes to come from the fire when it is first used and we recommend the area is well ventilated. 

a. 

Check to ensure the  Pressure Relief Door, at the top of the fire, is closed - see Section 15.

 

b.   

Check that the Glass Panel is fitted securely and sealed.  

c.   

Sometimes fumes from the fire can be mistaken for odours that will naturally burn off the fire when it is first operated from new  

      or during periods of little use and we recommend that the fire is run at maximum with doors/windows open to ventilate the room.  
 

See Important Note in Section 18 under Testing, Commissioning & Use. 

d.  

Fumes can be coming specifically from inferior Fire Surround materials e.g. resins from conglomerate materials which  

     we do not recommend rather than natural surround materials.

 

e. 

Fumes can also come  form materials like the resins used with Fibre Glass if this type of product as been used.   

 

IF THERE IS ANY DAMAGE FOUND ON THE GLASS PANEL IT MUST BE REPLACED BEFORE THE FIRE IS USED. 

 

ALWAYS CONDUCT A GAS SOUNDNESS CHECK AFTER SERVICING. 

 

ALWAYS RESEAL THE PRESSURE TEST POINT AND CHECK THAT IT IS GAS TIGHT. 

(This accounts for a lot of recalls.) 

 

ALWAYS CHECK THAT THE GLASS IS CLEAN AND FREE FROM FINGERPRINTS. 

(This accounts for a lot of recalls). 

 
 

Note: Marks on the Glass Panel are Not Covered by the Manufactures Warranty.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Fenton Balanced Flue

Page 1: ...be placed close to or on the fire We recommend that a Fireguard conforming to BS8423 should be used for protection of Young Children the Elderly Infirm and Pets ALL INSTRUCTIONS MUST BE LEFT WITH THE...

Page 2: ...rmity 32 23 Diagram of Infrared Control System 33 Guarantee 34 BOX CONTENTS The Fire comes in a number of boxes Box 1 Large box contains the Fire the Matrix Tray chosen Control System plus Fitting Kit...

Page 3: ...mm copper pipe gas supply to the burner via the isolation elbow 1 2 050mm length of 5mm x 4mm self adhesive silicone sealing strip for around the frame and base of the fire 1 1 820mm length of 5mm x 4...

Page 4: ...no nearer than 300mm to an opening in the building fabric formed for the purpose of accommodating a built in element such as a window frame The reference to external corners does not apply to building...

Page 5: ...a Safety Pressure Relief System and if the fires ignition should ever become delayed or noisy then the fire MUST NOT be used until checked by a Qualified Engineer Installer t In the event that the fi...

Page 6: ...y law and CE approval Commands are accepted by the microprocessor when buttons are pressed An audible beep means that the command has been received and the push button should immediately be released t...

Page 7: ...l Flame button to set the Minute Press Off or simply wait to return to the manual screen IMPORTANT For the following modes of controlling the fire automatically for Temperature or Timer Programs the F...

Page 8: ...ty alkaline e To change the Handset battery slide open the plastic panel on the back of the Handset f To change the Receiver Batteries remove the Ash Pan Cover and locate the electronic receiver box u...

Page 9: ...ners IMPORTANT NOTE The Fire MUST NEVER be used without the Glass Panel in place or if it is in any way damaged 4 SERVICING a The fire should be Serviced Annually in accordance with the Gas Safety Use...

Page 10: ...to comply with the above could leave the Installer Liable to Prosecution and Invalidate the Warranty IMPORTANT BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCT...

Page 11: ...he left of the centre of the fire and 39mm up from the base of the Fireplace Builders opening An isolation elbow is provided at the control inlet Your 8mm gas supply pipe needs to protrude through the...

Page 12: ...Construction Shelf Details Sections 11 12 13 are for the various Installation Applications for Traditionally Built Houses Only one will apply For Timber Frame Houses refer to Section 13 IMPORTANT NOTE...

Page 13: ...nd high humidity so it is very important that any rendering building work is allowed to thoroughly dry out before installation NOTE Take Care Not To Use Materials That Will Give Off An Odour When Hot...

Page 14: ...E INTERNAL WALLS e g Timber Wood Stud With or Without a Standard Rebated Fire Surrounds Back Panel or Slips 700mm Min 300 mm Min Flue Hole 160mm Dia Plaster Board Cut Back 25mm Around Flue Hole 454mm...

Page 15: ...t is very important that any rendering building work is allowed to thoroughly dry out before installation NOTE Take Care Not To Use Materials That Will Give Off An Odour When Hot As This Issue Is Know...

Page 16: ...Installation d Installation MUST take account of the Outer Wall Cladding be it Brick or Weather Boards the latter being combustible will require different Installation Requirements We recommend seeki...

Page 17: ...STIBLE MATERIALS AND SHELVES a A non combustible shelf can be fitted above the fire and should be positioned at least 95mm above the builders opening We recommend the depth of the shelf should be a ma...

Page 18: ...terial from inside the Flue d With the flue at the correct length and when the fire is fitted there should be 130mm of Flue Terminal Outside The Wall and the screw holes for fixing the Wall Plate shou...

Page 19: ...e drill the lower holes 27mm up from the base and drill the higher holes 510mm up from the base see Cable Fixing Diagrams on next page Secure the 4 Eyebolts supplied with the Rawl Plugs to the back of...

Page 20: ...t the Burner Assembly and secure with 4 screws reposition the Thermatronic Receiver Box and Infrared Sensor or for High Level Control the Battery Box onto their Velcro Pads if applicable Reposition Re...

Page 21: ...ear Matrix on top of the Matrix Tray Ensure it is sat up against the back and with TOP facing you c Slide the Front Matrix in front of the burner as shown with FRONT facing you Health Safety Advice Re...

Page 22: ...shown b Fit the Front Coal Cluster on top of the Front Matrix as shown c Fit 3off C coals up against the Rear of the fire as shown Set the C indent facing the back d Fit 2off B coals in the pocket in...

Page 23: ...ls to ensure they are located correctly stable and not overhanging the pockets Also ensure non of the identification letters stamped on the coals are visible j Before fitting the glass panel with the...

Page 24: ...Wood Coal Cluster on top of the Rear Matrix as shown b Fit the Front Wood Coal Cluster on top of the Rear Matrix as shown c Fit the Far Left Wood Piece into the Recessed area as shown d Fit the Far R...

Page 25: ...e Underside of the Wood into the Recesses as shown Finally adjust the Wood Pieces to ensure they are located correctly and stable h Before fitting the glass panel with the 5 special countersunk screws...

Page 26: ...d For Customers who have purchased the Thermatronic or High Level Controls explain and demonstrate that the batteries in the receiver and handset Thermatronic or Battery Box High Level should be repl...

Page 27: ...5 special countersunk screws p With the 2 Remote Control Systems Always exchange the Batteries in both the Handset and Receiver q With the 2 Remote Control Systems ensure they are operational with th...

Page 28: ...Disconnect the push on wire connections at the control Remove the switch and wires and replace with a new component in reverse order g All Control Systems have a Pressure Test Point to allow the Burne...

Page 29: ...portant Note in Section 18 under Testing Commissioning Use d Fumes can be coming specifically from inferior Fire Surround materials e g resins from conglomerate materials which we do not recommend rat...

Page 30: ...be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited Model Fent...

Page 31: ...must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited Model...

Page 32: ...ton Balanced Flue Certificate Number 19GR0277 00 The object of the declaration described above is in conformity with relevant harmonized legislation Gas Appliance Regulation EU 2016 426 The following...

Page 33: ...33 23 DIAGRAM OF RADIO FREQUENCY CONTROL SYSTEM...

Page 34: ...uring the return delivery to us We will not be liable for any such breakages Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval d...

Reviews: