background image

12 

 
 
 
 
 

10. Program and Review Length of Time Alert Trigger Will Last 

In programming mode, press <7> and input triggering time:  
 

<1>  = .5 seconds 
<2>  =  3 seconds 
 

and then press <ENTER>.   If entered correctly, the LED will display “A”,   then return to programming mode (“5”).       
 

Review Alert Trigger Duration   

In programming mode, press <3> and <7>  
The LED display will show the triggering time programmed (1 or 2), followed by two beeps. 

 
Note: The default triggering time is 0.5s. 
 

11. GSM Module Signal Strength Display 

In normal operating mode (

not

 programming mode), with the decimal point on the lower right corner flashing slowly, press <5> + <6> + 

<ENTER> to switch ON the GSM module signal strength display.  
 
The value will be 0-5, with 0 indicating the weakest (unable to send an alert) and 5 indicating the strongest signal.  

 

12. Stop Alarm State on Dialer 

While triggered, the E-AVDS-GSM will automatically send an alarm by dialing the numbers saved.  If a user wants to stop it, enter the 
password while the small “o” (upper segments of the LED display) is displayed.   If the password is accepted, the password will then 
be displayed,  the alarm state will be discontinued, and two beeps will be heard.    The E-AVDS-GSM  will return to normal operating 
mode.  
 
If the user enters the wrong code, the dialer will remain in an alarm state.   
 

 

13. Restore Factory Default Settings 

In programming mode, press <8> + <9><1><1> + <ENTER>.   The LED will display “A” if entered correctly and  
and return to programming state (“5”). 
 

Note:

 Most of the settings can be restored to factory default, except for the voice message recorded and triggering method (Need 

manually operation). 
 

14. Extra Information 

 

1.  If a SIM card is not installed or the E-AVDS-GSM is faulty, the LED will display “E” after initialization and will not function. 
 
2 Press <ENTER> to return to working state after finishing any programming operation.  If <ENTER> is not pressed and the LED  
continues to display “5” (programming mode), the dialer will not be able to acknowledge any alert triggers until it is returned to a 
working state. 

 

 
3. Do not use a SIM card with a PIN code protection feature. If the SIM card has this feature, insert the card in 
another mobile phone to disable the function (for example: using a Nokia mobile phone, choose: Menu

   

setting  

 

security setting 

   

PIN protection  

    

OFF). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for E-AVDS-GSM

Page 1: ...atically activates the phone or in this case the E AVDS GSM into which it is inserted SIM cards are available in three standard sizes The first is the size of a credit card 85 60 mm 53 98 mm x 0 76 mm...

Page 2: ...e down on a clean surface The Mini SIM card holder will be facing you 2 Slide the top of the card holder to the right A gap will appear between the top and bottom of the cardholder 3 Flip the top fram...

Page 3: ...sert the card all the way in until it stops 5 Fold the top frame back on top of the bottom The card should set into the same shaped recess in the bottom 6 Slide the top frame to the left to lock the f...

Page 4: ...this configuration a relay closure will trigger an alert state activating the dialer To set the normal relay state to Normally Closed apply the J2 and J1 jumpers to the center and left pins In this c...

Page 5: ...the front circuit board 2 With the screws removed carefully pull the rear circuit board off of the front circuit board Lift the circuit board straight up to separate them 3 Gently lay back the circui...

Page 6: ...ETHODS Connect the cable from the E AVDS GSM to the E xD according to one of the following diagrams Note The attached cable is 27 long but can be extended up to 250 feet with any 3 conductor 22AWG min...

Page 7: ...7...

Page 8: ...E1 through E8 indicators will illuminate while setting the password 5 GSM indicator a LED OFF GSM module power is OFF or doesn t work b 600ms milliseconds ON and 600ms OFF SIM card has not been insert...

Page 9: ...number followed by two beeps To clear and refresh the service provider phone number press 0 and then ENTER The LED will display A to indicate a correct input It will then automatically search for and...

Page 10: ...wer cycling the dialer allow it to restore connection with the service provider and try this procedure again If no SMS message is programmed the default SMS message sent will be DA 911 ALARM 6 Test Pr...

Page 11: ...message was sent successfully It will not follow the programmed number of retries 9 Save and Review Password The dialer supports a 4 digit private password Default password is 0911 To change the defa...

Page 12: ...word is accepted the password will then be displayed the alarm state will be discontinued and two beeps will be heard The E AVDS GSM will return to normal operating mode If the user enters the wrong c...

Page 13: ...one number and alarm receiving method Display alarm means 1 or 2 A then phone number followed by two beeps 4 Ex Test the recipient phone number and alarm receiving method Display A if successful Displ...

Page 14: ...ering duration 0 5 seconds or 3 seconds default is 0 5s Voice recording 20 seconds maximum Phone numbers Up to 8 contact numbers Private password protection 4 digit private password programmable Defau...

Reviews: