![NTI E-AVDS-GSM Installation And Operation Manual Download Page 11](http://html1.mh-extra.com/html/nti/e-avds-gsm/e-avds-gsm_installation-and-operation-manual_1715208011.webp)
11
Review Voice Alert Stop Method Programmed
In programming mode, press <3> and then <5>.
The 7-segment display will show 0, 1 or 2 followed by two beeps .
Note: When receiving an alert call, it is better to press <8> or <9> after the voice message has played after which you will
immediately hear two beeps. Then, if the stop command was successful, the user will hear a long beep.
8. Program and Review Alert Retries
In programming mode, press <6>, then enter the number of times the dialer should retry a number after a failed call
(enter 0-9), followed by <ENTER>. If entered correctly, the LED will display “A”, then return to programming mode (“5”). The
default number of retries is 5.
Note:
If you enter “0”, the dialer will retry an unlimited number of times.
Review Number of Programmed Retries
In programming mode, press <3> and then <6>.
The 7-segment display will show the number of retries programmed (0-9) followed by two beeps .
Note: For SMS alert messages, dialer will stop if the message was sent successfully. It will not follow the programmed
number of retries.
9. Save and Review Password
The dialer supports a 4-digit private password. (
Default password is 0911
) To change the default password, first enter programming
mode. Then press <PAUSE> , 4 digits, followed by <ENTER>.
Example:
If the desired private password is 1234, press <PAUSE> + <1><2><3><4>
+ <
ENTER>.
E1 through E8 LED indicators will illuminate while setting the password.
The dialer will beep twice and display a “0” indicating you have finished and the number has been accepted. The dialer will then
return to programming mode displaying a “5”.
If you enter more or less than 4 digits, system will display “E” and return to state “5”.
Review Password
In programming mode, press <3>. and then <PAUSE>. The LED will display the numbers in the password, followed by two beeps.
Note: If the user loses the programmed password, open the back cover and press the “RESET” button (see picture) using a
non-conductive (wood, plastic) object. Password will be changed to the default “0911”, but no other information/settings
will be lost. After pressing, the dialer will beep 3 times to indicate a reset.
Password Reset Button