LinMot
PROFIBNET Interface
Command Table: Save to Flash (Command ID 75h):
Word
DO
DI
1.
Parameter Channel Control
Parameter Channel Status
2.
-
-
3.
-
-
4.
-
-
For this command, the MC software must be stopped (with command “35h: Stop MC and
Application Software”).
The PROFINET Interface will stay active while the MC software is stopped.
Command Table: Delete All Entries (RAM) (Command ID 81h)
Word
DO
DI
1.
Parameter Channel Control
Parameter Channel Status
2.
-
-
3.
-
-
4.
-
-
Command Table: Delete Entry (Command ID 82h):
Word
DO
DI
1.
Parameter Channel Control
Parameter Channel Status
2.
Entry Number
Entry Number
3.
-
-
4.
-
-
Command Table: Write Entry (Command ID 83h)
Word
DO
DI
1.
Parameter Channel Control
Parameter Channel Status
2.
Entry Number
Entry Number
3.
Block Size (even number of bytes)
Block Size
4.
-
-
Command Table: Write Entry Data (Command ID 84h)
Word
DO
DI
1.
Parameter Channel Control
Parameter Channel Status
2.
Entry Number
Entry Number
3.
Data
Data
4.
Data
Data
Command Table: Get Entry (Command ID 85h)
Word
DO
DI
1.
Parameter Channel Control
Parameter Channel Status
2.
Entry Number
Entry Number
3.
-
Block Size
4.
-
-
Page 14/24
User Manual PROFINET Interface / 09/09/2015
NTI AG / LinMot