NTI AG LinMot E1030 Series Installation Manual Download Page 11

Controller Series E1030/2030/4030  

NTI AG  

Installation: E1030/E2030/E4030 series / 16.09.2005 

Page 11/12 

 

Declaration of Conformity CE-Marking 

 

Manufacturer:  

NTI 

AG 

 

 

 

LinMot 

®

 

  Haerdlistrasse 

15 

   8957 

Spreitenbach 

  

   Switzerland 
 

 

 

Tel.:  

+41 (0)56 419 91 91   

   Fax: 

 

+41 

(0)56 

419 

91 

92 

   
Products:  

LinMot 

®  

Controllers 

 

Type Art.-No. 

Type Art-No. 

Type Art.-No. 

E1030-DP 

0150-1625 

    

E2030-DP 

0150-1626 

    

E4030-DP 

0150-1628 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
The product must be mounted and used in strict accordance with the installation instruction contained 
within the User’s Manual, a copy of which may be obtained from NTI Ltd.  
 
I declare that as the authorized representative, the above information in relation to the 
supply/manufacture of this product is in conformity with the stated standards and other related 
documents in compliance with the protection requirements of the EMC Directive (89/336/EEC) and is 
marked in accordance with the CE Marking Directive (93/68/EEC). 
 
Standards Complied with: 
 

EMI 

EN 55011  

Class A 

EN 61000-6-4 

 

 

Electromagnetic 

EN 61000-4-2 

4 kV / 8kV 

Suspectibility EMC 

EN 61000-4-4 

1 kV / 2kV 

EN 61000-6-2 

EN 61000-4-3 

10 V/m 

 

EN 61000-4-6 

10 V 

 

ENV 50204 

10 V/m 

 
Company 
NTI Ltd. 
 
Zürich, February 24, 2003 
 

 
----------------------------------------------------------- 
R. Rohner  / CEO NTI Ltd.

 

Summary of Contents for LinMot E1030 Series

Page 1: ...30 DP E2030 DP E4030 DP Content IMPORTANT NOTES FOR E1030 E2030 E4030 SERIES CONTROLLERS 2 SYSTEM OVERVIEW 3 E1030 SERIES FUNCTION AND WIRING 4 POWER SUPPLY AND GROUNDING 5 DESCRIPTION OF THE CONNECTO...

Page 2: ...llers Do not switch Power Supply DC Voltage All power supply switching and E Stop breaks should be done to the AC supply voltage of the power supply Do not connect or disconnect the motors from contro...

Page 3: ...Motor 48 72 V From AC Mains 1x115V AC 1x230V AC RS232 Interface to PC for Configuration Linear Motor with internal Position Feedback Power Supply Signal 24 48 V Profibus DP address Profibus DP Interfa...

Page 4: ...30 4030 NTI AG Installation E1030 E2030 E4030 series 16 09 2005 Page 4 12 E1030 series Function and Wiring Picture shows typical wiring of a single axes controller Multiple axes controller will have a...

Page 5: ...n order to assure a safe and error free operation and to avoid severe damage to system components all system components must be well grounded to either a single earth or utility ground This includes b...

Page 6: ...Supply voltage for PWR Signal and PWR Motor may be different Motor Supply GND must be externally connected to earth Caution By exceeding 53VDC Power Supply Signal the controller will go into error st...

Page 7: ...tor wiring may damage Linear Motors and or Servo Controller If you are assembling motor cables by your own double check motor wiring carefully before power up Do not connect or disconnect the motors f...

Page 8: ...0 2030 4030 NTI AG Installation E1030 E2030 E4030 series 16 09 2005 Page 8 12 DP Profibus Connector DSUB 9 female Isolated 5V output max 50 mA Profibus ID ID High ID Low ID 1 Profibus address high ID...

Page 9: ...es 16 09 2005 Page 9 12 Mechanical Dimension Dimensions 295 64 90 330 179 Centers 315 Fixings for 2 x M5 screws Recommended mounting for multiple controller installation Fixings for 2 x M5 screws LinM...

Page 10: ...pplications Controller Voltage Power LinMot Switched Power Supply Part Nr E1000 1 motor 72 V 300 W S01 72 300 0150 1942 E2000 Up to 2 motors 72 V 600 W S01 72 600 0150 1943 E4000 Up to 4 motors 72 V 6...

Page 11: ...within the User s Manual a copy of which may be obtained from NTI Ltd I declare that as the authorized representative the above information in relation to the supply manufacture of this product is in...

Page 12: ...supply voltage for the Power circuitry is too low 3x l l l l The supply voltage for the Power circuitry is too high 4x l l l l The supply voltage for the Signal circuitry is too low 5x l l l l The sup...

Reviews: