500-1-030
13
Rev I: 2006.05.04
Helpful Hints
•
CAUTION:
If the iPAQ has not been charged for several days, the captured data on the
iPAQ may be lost. It is critical that you pull the data off the iPAQ and save it to your PC or
a memory card.
•
Charge both GreenSeeker Hand Held™ and iPAQ batteries completely before going to the
field. The internal battery is fully charged when the charger LED is green. The iPAQ
battery is fully charged when the amber LED is on solid.
•
Make sure to clear enough memory on your iPAQ before going to the field.
•
Make sure the Sensor is approximately parallel to the area being sensed.
•
Adjust the shoulder strap and PDA mount so the Sensor can be held comfortably.
•
Before going to the field, test the Sensor using the steps outlined in the Sensor
Performance section.
•
To disable the buzzer:
1.
Open the Control Box by removing the four screws in the corners with a Phillips head
screwdriver.
2.
Carefully separate the two halves of the box making sure the cables remained plugged
in.
3.
Remove the black jumper from J5 on the yellow connector PCB (ASSY 400-1-014).
4.
Close the Control Box and reinstall the four screws.
•
If you do not have a current version of Microsoft ActiveSync, go to
http://www.microsoft.com/downloads/
and select ActiveSync from the
“Product/Technology” pull-down menu. Follow the instructions for downloading and
installing the software.