OPTION - ACCESSORY CLEANING
Preparing the Accessories:
•
Select the correct tool for the job to be performed.
•
Connect the solution hose to the quick connect at
the back, lower left side of the machine and on the
tool.
•
To connect a tool, pull back on the collar of the
quick connect, insert one end of the solution hose
fitting and push it in until it locks. Attach the other
end of the solution hose to the tool in the same
manner.
•
Remove the machine hose from the
right side
of
the vacuum lid and insert one end of the recovery
hose into the lid. Attach the other end of the hose
to the accessory tool.
Cleaning upholstery, stairs or confined areas:
•
Prepare the solution / recovery tanks as you would
for normal carpet cleaning.
•
To begin cleaning, turn on the rocker switch for the
solution pump and vac motor only. When you
squeeze the trigger of the accessory tool it will
spray the cleaning solution, release the trigger to
stop the spray.
•
Do not apply water more than twice in one area
to prevent excess wetting.
•
Over-wetting can damage upholstery and / or
fabric.
Priming the Solution Pump
During normal use the clean solution tank may run
dry. This will allow air to enter the pump and solution
lines. Air in the solution lines will prevent the pump
from working properly, you must prime the pump.
•
Refill the solution tank.
•
Disconnect any accessory tool that may be in use.
CAUTION
- place machine near a floor drain prior to
the next step.
•
Turn on the solution pump switch.
•
Depress the center pin in the accessory quick
connect for 60 - 90 seconds (minimum). The pump
will spray air and solution out until all of the air has
been forced from the solution lines. When all of the
air has been expelled you may resume your
cleaning operation.
NOTE:
The solution pump will not prime through the
spray jets or an accessory tool.