background image

TROUBLE SHOOTING CHART CONTINUED 

Problem Cause 

Solution 

Front of machine does 
not move down to the 
floor when turned on. 

Spring guides sticking in slides.  

Check spring guides for proper operation. 
Replace if bent. Lubricate if necessary. Loosen 
bolts in spring guide mounting bracket, it will 
self align, retighten bolts. 

Flashing number 1 
appears in battery 
meter.

Brush motor circuit closed when machine is 
turned on.  

Turn off brush switch. Check tilt switch for 
proper operation. 

Flashing letter A 
appears in battery 
meter.

Twist grip not in neutral when master switch is 
turned on. Potentiometer not set properly in 
neutral position. 

Let go of twist grip. Have an authorized NSS 
Service Station reset the potentiometer to 
neutral or replace. 

Fault code F12 appears 
in battery meter. 

Internal programmable parameter data is 
corrupt.

Turn machine off and then on. If problem 
continues call for service.  

Fault code F23 appears 
in battery meter. 

Internal temperature of controller has exceeded 
the set parameters. 

Turn machine off and let control system cool off. 
If problem continues call for service.  

Fault code F26 appears 
in battery meter. 

Precharge failure when controller is turned on or 
the control system has been miswired causing 
an internal controller failure. 

Turn machine off and then on. If problem 
continues call for service.  

Fault code F29 appears 
in battery meter. 

Internal control system failure. 

Turn machine off and then on. If problem 
continues call for service.  

Fault code F32 appears 
in battery meter. 

Internal control system failure. 

Turn machine off and then on. If problem 
continues call for service.  

Fault code F37 appears 
in battery meter. 

Internal control system failure. 

Turn machine off and then on. If problem 
continues call for service.  

Fault code F42 appears 
in battery meter. 

The brush motor is exceeding the current limit 
set in the controller.  

Check the gas springs for wear. Check the 
brush pressure set collars for proper 
adjustment. Check pad driver and Flexiwall 
shield for proper installation and problems. Turn 
machine off and then on. If problem continues 
call for service.  

Fault code 
F44/F4C/F45/F59/F60 
appears in battery 
meter.

Caused by wiring short circuit in drive wiring or 
shorted drive motor. 

Check wiring and drive motor for short circuit. 
Correct problem if found. If problem continues 
call authorized NSS Service Station for service.  

Fault code F4D/F46/F61 
appears in battery 
meter.

Caused by wiring short circuit in brush wiring or 
shorted brush motor. 

Check wiring and brush motor for short circuit. 
Correct problem if found. If problem continues 
call for service.  

Fault code F58 appears 
in battery meter. 

The deceleration of the brush motor or drive 
motor exceeded set parameters. Example: 
Tried to slow down or stop on too steep a hill. 

Turn machine off and then on. If problem 
continues call authorized NSS Service Station 
for service.

Fault code F62 appears 
in battery meter. 

Internal control system failure. 

Turn machine off and then on. If problem 
continues call for service.  

Fault code F63 appears 
in battery meter. 

Caused by wiring short circuit in contactor 
wiring or contactor coil. 

Check wiring and contactor for short circuit. 
Correct problem if found. If problem continues 
call for service.  

Repairs performed by an unauthorized company will void the machine warranty. 
If you require assistance finding an authorized service center, contact NSS Enterprises.

NSS

®

 Enterprises, Inc.

3115 Frenchmens Road, Toledo, Ohio 43607 
PHONE (419) 531-2121 FAX (419) 531-3761 

NSS ® Enterprises, Inc. European Distribution Centre 

Unit II, Pinfold Trading Estate * 55 Nottingham Road 
STAPLEFORD, NOTTINGHAM NG9 8AD ENGLAND U.K. 
PHONE: (44) 0115 939 1568 * FAX: (44) 0115 949 0615 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for CHARGER 2717 DB

Page 1: ...l air openings free of dust lint hair etc x NEVER pick up anything that is burning or smoking such as cigarettes matches or hot ashes x NEVER allow this machine to be used as a toy Close attention is...

Page 2: ...batteries only does not apply to gel cell or maintenance free batteries x ALWAYS check to ensure the battery water level covers the battery plates before charging x ALWAYS check water level after cha...

Page 3: ...position by grasping the handle and moving it to the desired position x Turn on master switch and key switch if so equipped Wait until you hear a click the machine is now on See Machine Components fo...

Page 4: ...r The battery charger is located on top of the battery box cover x This high efficiency battery charger is designed for onboard operation Master Switch x The master switch is located on the top right...

Page 5: ...e of pads available for many different burnishing applications Consult your local NSS authorized distributor for application recommendations x Lift the front of the machine up to the 90 degree positio...

Page 6: ...on With the master switch turned off put the brush head into the pad change position Turn the brush switch on then the master switch on the machine should turn on x If the machine does not turn on and...

Page 7: ...grade bearing grease Failure to lubricate casters will cause the machine to maneuver with difficulty and premature failure of the caster will result x Lubricate the drive wheel bearings with an indust...

Page 8: ...acid when installing batteries See Battery Warnings on page 2 x Remove the side panel and top cover There are two bolts one in each corner on top of the side panel and two nuts one in each corner at...

Page 9: ...d of the gas spring against a hard surface and push on it If you can compress it it must be replaced If you can not compress it it is most likely OK Pad Pressure Adjustment The NSS Charger 2717 DB is...

Page 10: ...6 is again displayed after interrupting AC power for at least 10 seconds the charger must be brought to a qualified service depot Battery Maintenance Instructions 1 For flooded lead acid batteries reg...

Page 11: ...y Short run time on battery charge Incorrect Algorithm setting in battery charger for battery pack installed in machine Check Algorithm setting in battery charger and change if necessary Battery charg...

Page 12: ...ter The brush motor is exceeding the current limit set in the controller Check the gas springs for wear Check the brush pressure set collars for proper adjustment Check pad driver and Flexiwall shield...

Reviews: