Instruction AC-1406
Brüel & Kjær Vibro GmbH
Phone: +49 6151 428-1400
AC-1406 / C108243.001/ V01
Leydheckerstrasse 10
Fax: +49 6151 428-1401
© Brüel & Kjær Vibro
D-64293 Darmstadt
E-Mail:
08/2022 / Page 2 of 2
EN
ferule without
isolation
Cable screen
flush cutted,
additional wire
tinned
L = Cable length
N
OTE
This manual is a part of the product. Read the manual carefully before using the product and keep it safe
and easily accessible for future use.
Application
The
two-core connection cable AC-1406 is suitable for the connection of sensors and transmitters with 4-pole
M12-plug to a machine monitoring system.
Technical data
•
Plug design:
M12, 4-pole, female,
angled plug
•
Cable length L
5,0 m; 10,0 m
•
Number
of conductors
4
•
Conductor
cross section
4 x 0,34 mm²
•
Conductor resistance
≤ 5mΩ
•
Shield connected to union nut
•
Bending radius
min. 26 mm static /
min. 62 mm dynamic
•
Outer jacket
PUR, black
•
Outer diameter
5,1 mm
•
Operating
temperature range -30 °C .. +90 °C
•
Storage
temperature range -40 °C .. +90 °C
•
Mating cycles
min. 100
•
IP-protection
acc. to EN 60529 IP65, IP67, IP68
Connection
Install the connecting cable by putting the correctly aligned plug onto the sensor. Tighten the union nut. Press the
plug further towards the sensor. Repeat this process as often as necessary until the plug cannot be pressed any
further into the socket. Then tighten the union nut. For deinstallation, proceed in the reverse order.
NOTE:
Check for function and damage to the cable prior to each commissioning. Replace damaged cables
immediately.
Fig 1)
Pin configuration of the M12-cable connector
Order code:
AC-1406/xxxx/x
0050 = 5 m
0100 = 10 m
1 = with steel protective conduit