NSFOCUS ADS NX3 10000 Series Installation Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version: V4.5R90F02 (2020-02-28) 

NSFOCUS ADS

 

Installation Guide

 

© 2020 NSFOCUS 

Summary of Contents for ADS NX3 10000 Series

Page 1: ...Version V4 5R90F02 2020 02 28 NSFOCUS ADS Installation Guide 2020 NSFOCUS...

Page 2: ...t for the content of this document including but not limited to the layout figures photos methods and procedures which are protected under the intellectual property and copyright laws No part of this...

Page 3: ...7 1 1 5 ADS NX5 10000 Series 8 1 2 Power Supply 12 1 3 LEDs 15 1 4 Monitor 17 1 5 System Information 17 2 Preparations 22 2 1 Accessories Supplied with the Device 22 2 2 User provided Tools and Devic...

Page 4: ...System Maintenance 35 5 1 System Update 35 5 2 Common Troubleshooting 36 5 2 1 Web Login Failure 36 5 2 2 ADS Access Failure 36 5 2 3 License Import Failure 36 5 2 4 MAC Address Learning Failure 37 5...

Page 5: ...with the HTCA SFPP16TX4 interface 9 Figure 1 10 Front panel of ADS NX5 10000 with the HTCA CXP2SFPP20 interface 10 Figure 1 11 Front panel of ADS NX5 10000 with the HTCA QSFP28x6QSFP4SFPP16 interface...

Page 6: ...s 15 Table 1 7 Meanings of MGR LEDs in different states 16 Table 1 8 Meanings of ACTN LEDs in different states 16 Table 1 9 Meanings of the system LED in different states 16 Table 1 10 Meanings of int...

Page 7: ...ADS NX5 10000 ADS NX3 HD2500 and NX5 HD4500 6500 This document provides guidance for you in use of the products Descriptions in this guide may slightly differ from actual products due to version upgr...

Page 8: ...Concerning Product Disposal Provides tips on disposing of security devices Conventions Convention Description Bold font Keywords names of screen elements like buttons drop down lists or fields and us...

Page 9: ...8 164 0673 or 44 808 164 0NSF Australia 61 2 8599 0673 or 61 2 8599 0NSF Netherlands 31 85 208 2673 or 31 85 208 2NSF Brazil 55 13 4042 1673 or 55 13 4042 1NSF Japan 81 3 4510 8673 or 81 3 4510 8NSF S...

Page 10: ...of ADS devices The interface model or quantity of actual products may slightly vary with the batch or model 1 1 1 ADS NX3 2000 Series and NX5 4000 6000 Series ADS NX3 2000 series NX5 4000 series and N...

Page 11: ...orking interfaces Rear Panel Figure 1 2 Rear panel ofADS NX5 4020 Ground connector Power switch Power LED Power port 1 1 2 ADS NX3 HD2500 and NX5 HD4500 HD6500 ADS NX3 HD2500 and NX5 HD4500 HD6500 use...

Page 12: ...system LED STA status LED RJ45 console port USB port Management interface Hot standby port Expansion slot Monitor HDD caddy Rear Panel Figure 1 4 Rear panel ofADS NX5 HD4500 Ground connector Fan Powe...

Page 13: ...ement interface S console port RJ45 USB port Working interface 10G interface Working interface 10G interface Expansion interface Expansion interface Figure 1 6 Rear panel ofADS NX5 8000 Power supply 1...

Page 14: ...1000M adaptive straight through network cable Figure 1 8 Rear panel ofADS NX3 200E 600E 800E Ground connector Power switch Power port 1 1 5 ADS NX5 10000 Series 1 1 5 1 Front Panel The front panel of...

Page 15: ...00 with the HTCA SFPP16TX4 interface Working interface electrical Working interface 10G Working interface 10G MGT IPMI CONSOLE RJ45 USB port PWR power LED MGR status LED STAT status LED ACTN IPMI stat...

Page 16: ...th the HTCA CXP2SFPP20 interface Working interface 100G CXP Working interface 10G Working interface 10G MGT IPMI CONSOLE RJ45 USB port PWR power LED MGR status LED STAT status LED ACTN status LED HTCA...

Page 17: ...ADS NX5 10000 with the HTCA QSFP28x6QSFP4SFPP16 interface Working interface 100G Working interface 40G Working interface 10G Working interface 10G MGT IPMI CONSOLE RJ45 USB port PWR power LED MGR sta...

Page 18: ...y connect the ADS device to two independent power supplies to implement 1 1 power redundancy In this case even if one of the power modules fails the ADS device still operates properly The power switch...

Page 19: ...tandby 6 5 4 active 1 standby Table 1 2 describes AC power LEDs in different states Table 1 2 Meanings ofAC power LEDs in different states LED Status Meaning AC On yellow The AC LED being on after the...

Page 20: ...tions of a single DC power supply module are as follows Rated voltage range 39 to 76 V DC Maximum output power 1000 W Table 1 3 describes DC power LEDs in different states Table 1 3 Meanings of DC pow...

Page 21: ...tates LED Status Meaning Green Indicates that the system works properly Red Indicates that the engine works improperly Status LED STAT Table 1 6 describes STAT LEDs in different states These LEDs are...

Page 22: ...s of one service card Table 1 8 Meanings ofACTN LEDs in different states LED Status Meaning On Orange Indicates that the IPMI connection of the related board is normal Off Indicates that the related b...

Page 23: ...ayed on the first line 2 The second line shows the current status of the device as shown in Table 1 11 Table 1 11 Device status displayed on the monitor Displayed Content Meaning Initializing The devi...

Page 24: ...nterface reserved for the 10 Gigabit card that you can purchase from NSFOCUS 1 8 x GE optical port optional 1 8 x GE electrical port optional Weight 12 kg Height 88 mm 2U Depth 440 mm Width 564 mm Rac...

Page 25: ...E SFP interface reserved for the 10 Gigabit card that you can purchase from NSFOCUS 1 8 x GE optical port optional 1 8 x GE electrical port optional Weight 13 1 kg Height 88 mm 2U Depth 435 mm Width 5...

Page 26: ...0M Ethernet optical port optional 1 8 x 1000M Ethernet electrical port optional Weight 16 5 kg without packing weight Height 88 5 mm 2U Depth 626 mm Width 443 mm Rack 19 inch rack Power Supply AC redu...

Page 27: ...C Table 1 16 lists hardware specifications of ADS NX5 10000 Table 1 16 Hardware specifications ofADS NX5 10000 Interface 1 x RJ45 serial port 4 x 1000M electrical port optional 16 or 20 x 10G optical...

Page 28: ...nting ear used to fasten the device to the rack Rack mounting screw used to fasten the device to the rack Console port cable used for the configuration of the device console Accessories supplied may v...

Page 29: ...arge ESD wrist strap 2 3 Other Requirements Environment Good ventilation and heat elimination system on the installation site Temperature 0 45 C Relative humidity 10 95 non condensing ESD precaution T...

Page 30: ...NSFOCUS ADS Installation Guide Copyright NSFOCUS 24 V4 5R90F01SP07C236 2019 11 19 3 Installation Procedure 3 1 Installation Process Figure 3 1 Installation flowchart...

Page 31: ...immediately flip back to the original position Step 5 Check the status of the power LED on the front panel of the ADS device For details on the power LED and status LED see Table 1 4 and Table 1 5 End...

Page 32: ...he network However to achieve the optimal performance you are advised to connect it to the switch on the backbone network of the intranet After deployment please adapt network settings immediately to...

Page 33: ...for enterprises intranets that are characterized by fewer servers and smaller outgoing bandwidth In this mode an ADS device is transparently deployed at the network entry to detect analyze and block...

Page 34: ...NSFOCUS ADS Installation Guide Copyright NSFOCUS 28 V4 5R90F01SP07C236 2019 11 19 Figure 3 3 Out of path deployment of an ADS device...

Page 35: ...2 Network Configuration on the Console To perform configurations on the web based manager do as follows Step 1 Use a crossover cable included in the accessory box to connect the working interface on t...

Page 36: ...quired Step 1 Configure the IP address Since ADS devices support IPv4 IPv6 dual stack you can configure the IP address subnet mask and IPv6 address prefix length for the management interface IPv4 addr...

Page 37: ...in Figure 4 1 Figure 4 1 Security alert page Step 3 Click Continue to this website not recommended to accept the channel secured by NSFOCUS NIPS certificate Step 4 In the login page shown in Figure 4...

Page 38: ...rough 10 0 or Chrome with the resolution of 1024x768 or higher If you use the Internet Explorer based tabbed browsers such as MyIE and Maxthon or browsers that are not based on the Internet Explorer c...

Page 39: ...rs License Info Figure 4 5 shows the initial license page Figure 4 5 License Info page before the import of a license Step 2 Click Browse to browse to an ADS license file To get an ADS license file pl...

Page 40: ...nfigure network parameters as required Choose System Local Settings Basic Settings and click Edit to the lower right of the list to configure network parameters Then click Save in the upper right corn...

Page 41: ...upgrade Step 2 Click Browse select an update package and then click Start Upgrade During the update you need to wait patiently until a message indicating successful update appears Step 3 After an upd...

Page 42: ...le 5 2 2 ADS Access Failure Symptom ADS is not accessible though its threshold is not reached yet Troubleshooting Check whether the device that is directly connected to ADS has a hub or not A hub coul...

Page 43: ...or the optical fiber There once was a MAC learning problem caused by the optical module with too high power Changing the optical module addressed the problem If the connected interface is an electrica...

Page 44: ...tings IP Address 192 168 1 100 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 A 2 Default Web Administrator Account User Name admin Password nsfocus A 3 Default Console Administrator Account User Name...

Page 45: ...agement IP Address of Service Board 2 192 168 0 102 Subnet Mask 255 255 255 0 Management IP Address of Service Board 3 192 168 0 103 Subnet Mask 255 255 255 0 Management IP Address of Service Board 4...

Page 46: ...s expired Deliver them to a qualified recycling station after separating them from household waste The treatment method should conform to national laws and regulations concerning comprehensive utiliza...

Reviews: