NSE UC-100 User Manual Download Page 12

3 Installation and Operation Instructions

3.1 Installation

The product needs to be installed before using. Please follow the steps as 
below:

a) Take out the lens cap from the camera unit, then connect the C type 
optical adapter to the lens mount (C-Mount) located in the camera unit, 
clockwise rotate it to tighten it up.

b) Open the lock of the optical adapter, connect the endoscope, and release 
the lock to fix it.

c) Connect the self-locking connector of LED light to the lighting interface in 
camera unit, and connect the other end of the LED light to endoscope, 
clockwise rotate it to tighten it up.

7

Fig.3 Product Installation

Endoscope

Optical adapter

USB Cable

LED Light

Camera Unit

Summary of Contents for UC-100

Page 1: ...Model UC 100 USB HD Endoscopic Camera System User Manual A 0...

Page 2: ...re is easy for you to get for reading at any time When you don t read the manual please put it to a place where it will not be lost or damaged For safety and correct operation the following warning ma...

Page 3: ...good condition If any spare part is incomplete or damaged please contact with your supplier Please keep the packing materials well for future use Check the spare parts provided Caution Main Unit Quali...

Page 4: ...1 9 Requirements for Computer 1 10 Label and Symbol8 2 Product Structure 2 1 Product Diagram 2 2 Button Functions 3 Installation and Operation Instructions 3 1 Installation 3 2 Operation Instructions...

Page 5: ...11 11 12 12 12 13 5 3 Video is not smooth 5 4 Image is fuzzy 5 5 There is dark spot in image 6 EMC Information 7 After Sales Service Appendix A EMC Information...

Page 6: ...nsor micro controller and light source interface 1 4 Scope UC 100 is used with medical optical endoscope for real time observation and recording in endoscopy and minimally invasive surgery The real ti...

Page 7: ...0 7A supplied by computer USB3 0 port 1 8 Technical Parameters Image sensor type CMOS Video resolution 1920 1080 30fps Interface type USB3 0 Optical adapter Support all kind of C type optical adapter...

Page 8: ...ion Refer to attached file Type BF Recyclable Keep away from fire CE mark Follow instructions for use Name and address of the manufacture Name and address of European Representative Product LOT Number...

Page 9: ...gen or nitrous oxide vi Manufacturer will provide circuit diagrams component part lists descriptions calibration instructions to assist to SERVICE PERSONNEL in parts repair vii Additional equipment co...

Page 10: ...2 Product Structure 2 1 Product Diagram 5 Camera Unit Lighting Interface USB Cable Fig 1 Product Diagram...

Page 11: ...Button and button are used for reserved functions Button is used for LED light brightness adjustment and shut LED light brightness can be adjusted from level 1 to level 5 6 Fig 2 Buttons Customizable...

Page 12: ...unt C Mount located in the camera unit clockwise rotate it to tighten it up b Open the lock of the optical adapter connect the endoscope and release the lock to fix it c Connect the self locking conne...

Page 13: ...he LED light is the application component connected to the endoscope 3 2 Operation Instructions After the installation of endoscope please connect the UC 100 to the USB3 0 port of computer After conne...

Page 14: ...sight the LED light beam in short distance Warning Please do not disassemble the product and spare parts like LED light etc Any malfunction or failure please stop using it and contact with your distr...

Page 15: ...Install Driver After you connect the UC 100 to the computer correctly the software can t open the camera device or there is a yellow mark in the device icon in computer device management Please refer...

Page 16: ...may loose causing the video interruption please reconnect UC 100 to computer 5 3 Video is not smooth Please make sure the using computer configuration is above the minimum requirements 5 4 Image is f...

Page 17: ...ic interference such as near mobile phones microwave ovens Caution Guidelines and manufacturer s statement detailed in the annex Warning The device or system should not be close to or stacked with oth...

Page 18: ...s declaration electromagnetic emissions The UC 100 is intended for use in the electromagnetic environment specified below The customer or the user of the UC 100 should assure that it is used in such...

Page 19: ...utput line 1 kV line s to line s 2 kV line s to earth 8 kV Contact discharge 15 kV Air discharge Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relati...

Page 20: ...l commercial or hospital environment If the user of the UC 100 requires continued operation during power mains interruptions it is recommended that the UC 100 be powered from an uninterruptible power...

Page 21: ...the equation applicable to the frequency of the transmitter Recommend isolation distance d 1 2 d 1 2 80 MHz to 800 MHz d 2 3 800 MHz to 2 5 GHz where P is the maximum output power rating of the transm...

Page 22: ...dditional factor of 10 3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in these frequency ranges c Field strengths from fixed transmi...

Page 23: ...the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distanc...

Page 24: ...between 150 kHz and 80 MHz and in the frequency range 80 MHz to 2 5 GHz to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...ternational Holding Corp GmbH Europe Eiffestrasse 80 20537 Hamburg Germany Rm 102 1 202 1 NO 5 Tianfeng Rd Science City Guangzhou Development District 510530 Guangzhou Guangdong PEOPLE S REPUBLIC OF C...

Reviews: