G-13.mft MDB/S1
46
National Rejectors, Inc. GmbH, Buxtehude
Implemented S1 commands
Byte 1
Byte 2
Command
Data
[Bytes
expected/
returned]
00h
–
Reset
[0/ACK]
01h
–
Status
[0/30]
03h
–
Poll
[0/1..16]
04h
–
Coin Type
[4/ACK]
06h
–
Change Default Value
[9/ACK]
07h
00h
Expansion Command Identification
[0/33]
07h
01h
Expansion Current Value
[0/13]
07h
03h
Expansion Command Diagnose 1[0/ACK]
07h
04h
Expansion Command Diagnose 2
[0/5]
S1 status and error codes (reply to poll)
Byte 1
Meaning
00h – 10h
Status and error messages
11h – 1Fh
vacant
20h – 3Fh
Slug counter
40h – 4Eh
Error with coin acceptance
4Fh – 5Fh
vacant
60h – 67h
Sort-info way 0–7
68h – 7Fh
vacant
80h – 8Fh
Coin info with successful acceptance
9Fh – FFh
Coin info with incorrect acceptance
S1 standard settings (following reset)
All settings performed by the vending machine control system are transient.
Following a reset operation, the following standard settings are applicable
until the control system changes any settings:
Description
Value
Sorting way, cash-box
0
Sorting ways of coins 1..16
predefined setting acc. to data block
Sorter override (coin in cash-box) 0 (each coin will be sorted)
Summary of Contents for G-13.mft MDB/S1
Page 2: ......
Page 6: ......
Page 43: ...G 13 mftMDB S1 TECHNICALDATA 43 National Rejectors Inc GmbH Buxtehude ...
Page 49: ...G 13 mftMDB S1 TECHNICALDATA 49 National Rejectors Inc GmbH Buxtehude View from the side ...
Page 52: ...TECHNICALDATA G 13 mftMDB S1 52 National Rejectors Inc GmbH Buxtehude View from the side ...
Page 54: ...TECHNICALDATA G 13 mftMDB S1 54 National Rejectors Inc GmbH Buxtehude View from right ...
Page 56: ...TECHNICALDATA G 13 mftMDB S1 56 National Rejectors Inc GmbH Buxtehude View from right ...