1.  Safety Regulations 

 
VERY IMPORTANT: Instruments and components supplied by npi electronic are NOT 
intended for clinical use or medical purposes (e.g. for diagnosis or treatment of humans), 
or for any other life-supporting system. npi electronic disclaims any warranties for such 
purpose.  Equipment  supplied  by  npi  electronic  must  be  operated  only  by  selected, 
trained  and  adequately  instructed  personnel.  For  details  please  consult  the GENERAL 
TERMS OF DELIVERY AND CONDITIONS OF BUSINESS of npi electronic, D-71732 
Tamm, Germany.
 
 
1)

 

GENERAL:  This  system  is  designed  for  use  in  scientific  laboratories  and  must  be 
operated by trained staff only. General safety regulations for operating electrical devices 
should be followed. 

 
2)

 

AC MAINS CONNECTION: While working with the npi systems, always adhere to the 
appropriate  safety  measures  for  handling  electronic  devices.  Before  using  any  device 
please read manuals and instructions carefully. 
The  device  is  to  be  operated  only  at  115/230  Volt  60/50  Hz  AC.  Please  check  for 
appropriate line voltage before connecting any system to mains. 
Always  use  a  three-wire  line  cord  and  a  mains  power-plug  with  a  protection  contact 
connected to ground (protective earth).  
Before opening the cabinet, unplug the instrument. 
Unplug  the  instrument  when  replacing  the  fuse  or  changing  line  voltage.  Replace  fuse 
only with an appropriate specified type. 

 
3)

 

STATIC  ELECTRICITY:  Electronic  equipment  is  sensitive  to  static  discharges.  Some 
devices such as sensor inputs are equipped with very sensitive FET amplifiers, which can 
be damaged by electrostatic charge and must therefore be handled with care. Electrostatic 
discharge  can  be  avoided  by  touching  a  grounded  metal  surface  when  changing  or 
adjusting  sensors.  Always  turn  power  off  when  adding  or  removing  modules, 
connecting  or  disconnecting  sensors,  headstages  or  other  components  from  the 
instrument or 19” cabinet.
 

 
4)

 

TEMPERATURE  DRIFT  /  WARM-UP  TIME:  All  analog  electronic  systems  are 
sensitive to temperature changes. Therefore, all electronic instruments containing analog 
circuits should be used only in a warmed-up condition (i.e. after internal temperature has 
reached  steady-state  values).  In  most  cases  a  warm-up  period  of  20-30  minutes  is 
sufficient. 

 
5)

 

HANDLING:  Please  protect  the  device  from  moisture,  heat,  radiation  and  corrosive 
chemicals. 

 
 

Summary of Contents for EXT-02F

Page 1: ...E EXT 02F EXTRACELLULAR AMPLIFIER WITH FILTERS One or Two Channel Recordings VERSION 4 2 npi 2015 npi electronic GmbH Bauhofring 16 D 71732 Tamm Germany Phone 49 0 7141 9730230 Fax 49 0 7141 9730240 s...

Page 2: ...______ version 4 2 page 2 Table of Contents 1 Safety Regulations 3 2 EXT 02F 4 2 1 Components 4 2 2 System Description 4 2 3 Description of the Front Panel 4 2 4 Description of the Rear Panel 8 2 5 He...

Page 3: ...e check for appropriate line voltage before connecting any system to mains Always use a three wire line cord and a mains power plug with a protection contact connected to ground protective earth Befor...

Page 4: ...of the two recording channels are identical The EXT 02F has a differential input with high input impedance to avoid noise The output voltage signal can be HIGH PASS or LOW PASS filtered and is availa...

Page 5: ...osition switch for selecting the corner frequency of the single pole HIGHPASS filter with 6 dB octave In OFF position the HIGHPASS filter is disabled DC recording Corner frequencies Hz 3 30 100 300 40...

Page 6: ...gnals greater than 1 V will be converted into a sound NOISE With an amplification of 10000 this correspondents to a signal of 100 V at the electrode 9 INPUT MODE switch Switch for selecting the INPUT...

Page 7: ...he HIGH PASS FILTER to 400 Hz Set the GAIN range switch to 1k and adjust the baseline to zero using the trimpot Set the GAIN range switch to 10k and adjust the baseline again if necessary 14 INPUT swi...

Page 8: ...are used the headstage must be disconnected Also very Important Setting both switches to OFF means that both inputs are grounded i e measurement is impossible This applies also if a headstage is used...

Page 9: ...ON A switch Switch that enables upper position or disables lower position the NOTCH filter optional 2 5 Headstage Option Figure 3 headstage optional and electrode holder optional and of the EXT 02F He...

Page 10: ...al input that minimizes noise pick up Differential means that the signal for the amplifier is the difference between the positive PEL at the headstage and negative REF at the headstage input of the am...

Page 11: ...______________________________ version 4 2 page 11 Figure 4 headstage connections A differential measurement B single ended measurement Hint The REF connector of the headstage can also be set to GND b...

Page 12: ...Electrical Activity of Individual Neurons In Situ Extra and Intracellular Recording in U Windhorst and H Johansson eds Modern Techniques in Neuroscience Research Springer Berlin New York Lambert F M...

Page 13: ...400 500 600 800 1k 3k 10k with OFF position LOWPASS Filter single pole attenuation 6 dB octave corner frequencies Hz 30 100 300 500 700 900 1 3k 1 5k 1 7k 3k 10k 20k NOTCH Filter Europe 50 Hz USA 60...

Reviews: