background image

EXT-02F User Manual 

___________________________________________________________________________ 
version 4.2 

 

 

page 12 

4.  Literature 

 

 

Barmashenko,  G.,  Eysel,  U.  T.,  &  Mittmann,  T.  (2003).  Changes  in  intracellular  calcium 
transients and LTP in the surround of visual cortex lesions in rats. Brain Res. 990, 120-128. 

 

Boulton,  A.  A.,  Baker,  G.  B.  &  Vanderwolf,  C.  H.  (eds.)  (1990).  Neurophysiological 
Techniques, Basic Methods and Concepts
. Humana Press, Clifton, New Jersey. 

 

Huemmeke,  M.,  Eysel,  U.  T.,  &  Mittmann,  T.  (2002).  Metabotropic  glutamate  receptors 
mediate expression of LTP in slices of rat visual cortex. Eur.J.Neurosci. 15, 1641-1645. 

 

Huemmeke, M., Eysel, U. T., & Mittmann, T. (2004). Lesion-induced enhancement of LTP 
in  rat  visual  cortex  is  mediated  by  NMDA  receptors  containing  the  NR2B  subunit.  
Physiol
 559 , 875-882. 

 

Schulz, D., Huston, J. P., Jezek, K., Haas, H. L., Roth-Harer, A., Selbach, O., & Luhmann, 
H.  J.  (2002).  Water  maze  performance,  exploratory  activity,  inhibitory  avoidance  and 
hippocampal  plasticity  in  aged  superior  and  inferior  learners.  Eur.J.Neurosci.  16,  2175-
2185. 

 

Kettenmann,  H.  &  Grantyn,  R.  (eds.)  (1992).  Practical  Electrophysiological  Methods
Wiley-Liss, New York 

 

Kowski, A. B., Veh, R. W., & Weiss, T. (2009). Dopaminergic activation excites rat lateral 
habenular neurons in vivo. Neuroscience. 161, 1154-1165. 

 

Lalley, P.M., A.K. Moschovakis and U. Windhorst (1999) Electrical Activity of Individual 
Neurons  In  Situ:  Extra-  and  Intracellular  Recording,  in:  U.  Windhorst  and  H.  Johansson 
(eds.) Modern Techniques in Neuroscience Research, Springer, Berlin, New York. 

 

Lambert,  F.  M.,  Beck,  J.  C.,  Baker,  R.,  &  Straka,  H.  (2008).  Semicircular  canal  size 
determines the developmental onset of angular vestibuloocular reflexes in larval Xenopus. 
Journal of Neuroscience 28, 8086-8095. 

 

Meuth,  S.  G.,  Aller,  M.  I.,  Munsch,  T.,  Schuhmacher,  T.,  Seidenbecher,  T.,  Meuth,  P., 
Kleinschnitz,  C.,  Pape,  H.  C.,  Wiendl,  H.,  Wisden,  W.,  &  Budde,  T.  (2006).  The 
contribution  of  TASK-1-containing  channels  to  the  function  of  dorsal  lateral  geniculate 
thalamocortical relay neurons. Molecular Pharmacology

 

Müller, Ch.M. (1992) Extra- and Intracellular Recording in the Slice, in: Kettenmann, H. & 
Grantyn, R. (eds.) Practical Electro-physiological Methods, Wiley-Liss, New York 

 

Ogden, D. (ed.) (1992) Microelectrode Techniques - The Plymouth Workshop Handbook, 
Second Edition, The Company of Biologists Ltd., Cambridge 

 

Schneider,  N.  L.  &  Stengl,  M.  (2006).  Gap  junctions  between  accessory  medulla  neurons 
appear  to  synchronize  circadian  clock  cells  of  the  cockroach  Leucophaea  maderae.  
Neurophysiol.
 95, 1996-2002. 

 

Seidenbecher,  T.  and  H.C.  Pape  (2001)  Contribution  of  intralaminar  thalamic  nuclei  to 
spike-and-wave-discharges  during  spontaneous  seizures  in  a  genetic  rat  model  of  absence 
epilepsy, European Journal of Neuroscience, Vol. 13:1537-1546 

 

Windhorst,  U.  and  H.  Johansson  (eds.)  (1999)  Modern  Techniques  in  Neuroscience 
Research, Springer, Berlin, Heidelberg, New York 

 

Summary of Contents for EXT-02F

Page 1: ...E EXT 02F EXTRACELLULAR AMPLIFIER WITH FILTERS One or Two Channel Recordings VERSION 4 2 npi 2015 npi electronic GmbH Bauhofring 16 D 71732 Tamm Germany Phone 49 0 7141 9730230 Fax 49 0 7141 9730240 s...

Page 2: ...______ version 4 2 page 2 Table of Contents 1 Safety Regulations 3 2 EXT 02F 4 2 1 Components 4 2 2 System Description 4 2 3 Description of the Front Panel 4 2 4 Description of the Rear Panel 8 2 5 He...

Page 3: ...e check for appropriate line voltage before connecting any system to mains Always use a three wire line cord and a mains power plug with a protection contact connected to ground protective earth Befor...

Page 4: ...of the two recording channels are identical The EXT 02F has a differential input with high input impedance to avoid noise The output voltage signal can be HIGH PASS or LOW PASS filtered and is availa...

Page 5: ...osition switch for selecting the corner frequency of the single pole HIGHPASS filter with 6 dB octave In OFF position the HIGHPASS filter is disabled DC recording Corner frequencies Hz 3 30 100 300 40...

Page 6: ...gnals greater than 1 V will be converted into a sound NOISE With an amplification of 10000 this correspondents to a signal of 100 V at the electrode 9 INPUT MODE switch Switch for selecting the INPUT...

Page 7: ...he HIGH PASS FILTER to 400 Hz Set the GAIN range switch to 1k and adjust the baseline to zero using the trimpot Set the GAIN range switch to 10k and adjust the baseline again if necessary 14 INPUT swi...

Page 8: ...are used the headstage must be disconnected Also very Important Setting both switches to OFF means that both inputs are grounded i e measurement is impossible This applies also if a headstage is used...

Page 9: ...ON A switch Switch that enables upper position or disables lower position the NOTCH filter optional 2 5 Headstage Option Figure 3 headstage optional and electrode holder optional and of the EXT 02F He...

Page 10: ...al input that minimizes noise pick up Differential means that the signal for the amplifier is the difference between the positive PEL at the headstage and negative REF at the headstage input of the am...

Page 11: ...______________________________ version 4 2 page 11 Figure 4 headstage connections A differential measurement B single ended measurement Hint The REF connector of the headstage can also be set to GND b...

Page 12: ...Electrical Activity of Individual Neurons In Situ Extra and Intracellular Recording in U Windhorst and H Johansson eds Modern Techniques in Neuroscience Research Springer Berlin New York Lambert F M...

Page 13: ...400 500 600 800 1k 3k 10k with OFF position LOWPASS Filter single pole attenuation 6 dB octave corner frequencies Hz 30 100 300 500 700 900 1 3k 1 5k 1 7k 3k 10k 20k NOTCH Filter Europe 50 Hz USA 60...

Reviews: