6000counts Intelligent scanning digital multimeter

7

/

7

2. The front end of the meter has NCV test points. As long as the point is close to the AC voltage, the buzzer will emit different continuations

according to the different strengths of the signals. At the same time, the LCD will display different number of segments according to the strength of

the signal.

五.

Automatic Startup & Shutdown

When the instrument stops using for about 15 minutes, the meter will automatically power off to enter the sleep state. To restart the power, press

and hold the

power

button for more than 2 seconds, the LCD will display

----

for automatic scanning, and the automatic shutdown symbol

APO

will be displayed. Press and hold the "hold" key while the power switch is turned on, the automatic shutdown function will be canceled, no

"APO" appears on the display.

symbol disappears, will cancel the automatic shutdown function.

六、

Troubleshooting

If your instrument does not work, the following method can help you solve the general problem, if the fault still can not be excluded, please

contact the service center or dealer.

Failure phenomenon

Inspection site and method

Not shown

Battery not connected

Replace the battery

Low battery symbol

Replace the battery

Current is not input

Replace fuse

Resistance display error

The test pen is not in contact

This manual is subject to change without notice;

The contents of this manual are considered correct. If the user finds any errors, omissions, etc., please contact the manufacturer;

The company does not bear the accidents and hazards caused by the user's wrong operation;

The functions described in this manual are not intended to reasons of the product for special purposes.

60000-0108D-181023

Summary of Contents for 6000Counts

Page 1: ...6000counts Automatic Scanning Digital Multimeter User s Manual Index 1 Overview 1 2 Safety Precautions 1 3 Characteristics 1 4 Operation panel instructions 3 5 Automatic boot 7 6 Troubleshooting 7 ...

Page 2: ...This series of instruments is designed in accordance with IEC1010 Safety Standards promulgated by the International Electrotechnical Commission please read the safety precautions before use 1 When measuring voltage do not input a limit voltage exceeding the effective value of DC 1000V or AC 750V 2 The voltage below 36V of the current file is a safe voltage 3 When changing functions and ranges the ...

Page 3: ...dity 75 calibration guarantee period from the date of manufacture for one year 2 2 Performance Note indicates that the table has this function Function DC voltage DCV AC voltage ACV DC current DCA AC current ACA Resistor Diode On Off Test Capacitor Frequency F Square wave output NCV Zero line FireWire test Full unit symbol Backlight manual Auto off True RMS measurement Temperature Flashlight light...

Page 4: ...rement button long press NCV button to measure electric field induction signal 5 HOLD is the data hold button long press for 2 seconds for the flashlight 6 Function selection key SELECT long press for 2 seconds to turn the power on and off 7 COM input negative input insert black test pen 8 10A current input port 9 Voltage resistance diode capacitor buzzer input port 图 1 ...

Page 5: ...nt The value is automatically switched between 6V 60V 600V 1000V and the measured value is displayed on the LCD Note 1 Do not exceed the input voltage of DC1000V or AC750V If it exceeds there is danger of damage to the instrument circuit When high voltage circuit pay special attention to avoid electric shock 2 After completing all measurement operations disconnect the test leads from the circuit u...

Page 6: ...irst and subtract the value when the test leads are shorted in the measurement readings 2 When measuring the on line resistance please make sure that all the circuits under test must be turned off and all capacitors fully discharged in order to ensure the measured value accurately 2 3 3 Fast turn off test diode capacitor Range Display value Test Conditions Diode forward voltage drop Forward DC cur...

Page 7: ...ad protection 10A The specific operations are as follows 1 The boot is displayed as an automatic scan status 2 Insert the black test lead into the COM jack and the red test lead into the V Ω jack the test leads are reliably in contact with the test point 3 When inputting more than 20mA current between COM and 10A the meter will display the large component on the LCD according to the size of the AC...

Page 8: ...he automatic shutdown function will be canceled no APO appears on the display symbol disappears will cancel the automatic shutdown function 六 Troubleshooting If your instrument does not work the following method can help you solve the general problem if the fault still can not be excluded please contact the service center or dealer Failure phenomenon Inspection site and method Not shown Battery no...

Reviews: