EN 9
GENERAL INFORMATION
General
These are the mounting instructions for the Novy hood with recirculation kit. Use these mounting instructions for both
the hood and the recirculation kit. The manual is a separate booklet that has been supplied with the hood. Carefully read
these instructions before installing and commissioning the island chimney hood. It is recommended to have one or more
qualified persons carry out the installation only.
Carefully take the hood from the packaging.
The hood is to be used above a cooking plate and/or domino and intended for household use only.
Important before mounting
Page 2 of these mounting instructions show the mounting drawings. Observe the following mounting tips before starting
the mounting activities:
• For easier mounting of the island chimney hood, it is recommended to do this with at least 2 persons.
• Check if all mounting materials have been supplied using the drawing on page 2.
• Position the wall socket such, that it is behind the shafts of the chimney hood.
• Make sure that the ceiling has sufficient load bearing capacity.
• Remove the protective film from the stainless steel of the island chimney hood or shafts before mounting. Avoid
damaging the stainless steel.
INSTALLATION
Proceed following the mounting drawings on page 2.
Preparations for mounting:
Draw the vertical axis A of the chimney hood on the wall. The recommended height ‘h’ between the bottom of the
chimney hood and the cooking plate is for
- gas: min. 65 cm and max. 80 cm
- induction: min. 75 cm and max. 80 cm
- other cooking plates: min. 65 cm and max. 80 cm
The level line B is drawn at the chosen height of ‘h’ + 440 mm.
Position the socket outlet near the vertical axis A within the width of the shafts and above the motor housing and
below the recirculation box (M).
Position the mounting plate (M) of the recirculation box in the middle of the vertical axis and against the ceiling. In
case of a stone wall, mark and drill the 3 holes (Ø 8 mm). Install the mounting plate (M) using the plugs (3x 906-055)
and screws (3x 906-143). In case of a wooden mounting wall, use the chipboard screws (3 x 906-192).
Position the recirculation box (H) on the mounting plate (M). Make sure when positioning the recirculation box that it
is not deformed or unfolded when mounting.
1. Let H rest on the protruding lip of M (see figure 5).
2. Tilt H towards the wall bracket M.
3. Hook the lip of H behind the wall bracket M.
Screw the recirculation box H onto the mounting plate M (4x 906-151).
Attention! Make sure that the attachment lip of H is always on the outside!
After having mounted the recirculation box, the wall-mounted chimney hood can be mounted. Use the mounted
materials supplied with the chimney hood for mounting the hood and the shafts.
The drilling jig is to be found in the mounting instructions of the wall-mounted hood. Place this drilling jig on the
crossing point of the axis A and the level line B and draw the 2 holes on the level line. Drill holes in the wall using an
8 mm drill.
Use the large plugs (906055) and partly screw the accompanying large screws (906143) into the wall. Attention: do
not fully screw in the screws yet!
Hang the wall-mounted chimney hood with the bracket on top of the motor housing over these screws.
Level the chimney hood C by turning the screws on the chimney hood such, that the chimney hood is hanging level.
The height of the chimney hood can slightly be adjusted by screwing the screws in and out.
Attention: do not tighten the screws in the wall yet!
Open the bottom plate and remove the fat filter from the chimney hood. There are 2 holes on the rear side of the
chimney hood. Mark these holes on the wall. Close the bottom plate and take the chimney hood off the wall in
order to be able to drill the marked holes. Drill the holes with a 6 mm drill and use the small plugs (906115). Position
the chimney hood against the wall again. Check if the hood is still hanging level. Use the small screws (906197) to
properly attach the wall-mounted chimney hood to the wall. Now also tighten the screws above in the wall.