Air supply
When using a hood sufficient air flow is neces-
sary. However large your kitchen may be, there is
only so much air available in that space. Opening
a door or window or the installation of a ventila-
tion grid close to the hood insures a good quality
of air flow.
Insufficient air flow will impair the extraction ef-
ficiency of your hood immensely.
Insufficient air flow can cause reflux from other
air ducts such as chimneys or combustion appli-
ances.
When using a cooker hood and appliances using
energy other than electrical in the same space,
the pressure in the room may not surpass 4 Pa (=
0.04mBar).
Safety
• Deep frying under the hood is only allowed un-
der constant supervision.
• Under no circumstances is it allowed to flambé
under the hood.
• In case of fire always switch off the hood.
• Never extinguish burning fat or oil with water.
Cover the pot with a well fitting lid or a burn-
blanket.
Advice
For maximum efficiency please follow this advice:
• When cooking make sure pots are positioned
properly under the hood surface.
• Activate the hood a few minutes prior to cook-
ing.
• Switch the hood off 10 minutes after cooking is
finished (use delay function when present).
• Avoid drafts under the hood surface.
• When using induction: adapt the intensity of
both hob and hood to the lowest possible level
in order to avoid excessive creation of damp
fumes.
Operation
①
switch on / off
②
decrease speed levels
⑤
and
⑥
speed indicator lamps
③
increase speed levels
④
illumination
Switch on - switch off
Once the drawer is opened, the light and the fan
can be turned on. By closing the drawer the light
and the fan will be turned off.
To switch the motor on push button
①
.
The hood will always resume the level it was
previously switched off in.
Auto-Stop
To avoid that the hood will function during a too
long period, it will switch off automatically after 3
hours (when no changes to the controls have
been made). Only the motor will turn off automati-
cally. The lighting will stay on.
Switch off with 10 minute delay:
Press button
①
once. The first green speed in-
dicator lamp blinks, the other speed indicator
lamps remain lit up according to the level in use.
After 10 minutes motor and illumination switch off
automatically.
Switch off without delay:
Push button
①
twice.
Levels of intensity
To decrease speed levels push button
②
. To in-
crease speed levels push button
③
.
Three green speed indicator lamps
⑤
indicate
level 1 to 3, one red speed indicator lamp
⑥
indi-
cates the level ‘POWER’.
‘POWER’ is only used in case of excessive forma-
tion of smoke, fumes or odours. Taking into ac-
count the large volume of air which is extracted
from the room at this level, it’s use should be lim-
ited.
‘POWER’ automatically reverts to level 3 after 6
minutes.
A self-rectifying thermal contact makes sure that
the motor is switched off when overheated. The
motor will switch on again after is has cooled
down. The cause of the overheating needs to be