NVIP-2DN5001H/IR-1P, NVIP-3DN5001H/IR-1P, NVIP-5DN5001H/IR-1P
User’s manual (short form) ver.1.1
All rights reserved © AAT Holding sp. z o.o.
11
Unscrew the locking screw and the stopping ring, and then manually point the camera in a
desired direction to obtain a desired scene view.
Firmly screw the locking screw and the stopping ring.
Adjust the camera zoom and focus as needed.
It is recommended to check focus settings in
infrared illumination and make correction in colour mode to have proper focus in both modes.
Close the service compartment and firmly screw the service compartment screws.
INSTALLATION
Locking screw
Tighten
Loosen
Horizontal/vertical rotation
Stopping ring
Focus
adjustment
Zoom
adjustment