User manual for Speed Dome Camera NVAHD-2DN3102SD/IR-1 ver. 1.0
All rights reserved © AAT Holding S.A.
10
2.2 Baud Speed Settings
Camera features DIP-switch blocks for configuring addresses and transmission parameters for RS-485
protocol. Switches are located under the cover located underneath camera module.
Camera has automatic protocol detection:
Automatic identify allows detection of speed, when using Pelco-D protocol.
In case using N-Control speed is fixed at 2400bps.
For
RS-485
connections,
RS485+
and
RS485–
wires should be used. They should be connected
to respective
TX+
and
TX–
connectors of the controller, e.g. NV-KBD50 keyboard. Next camera in the
cascade is connected also using same
RS485+
and
RS485–
connectors.
START-UP AND INITIAL CAMERA CONFIGURATION