NMS NVR X
-
4U, NVR X
-
2U/XX/R, NVR 7XE
-
4U
-
1.3 version
-
User
’
s manual
All rights reserved © AAT Holding S.A.
42
RAID CONTROLLER
7.2. DISC REPLACEMENT PROCEDURE THE NMS SERVER NVR X
-
2U/XX/R
Disk damage is indicated by a sound signal, as well as flashing the red LED in the storage pocket.
You should immediately check the status of the matrix and, if the need to replace the failed drive.
RAID 5 allows one disk failure without loss data. The figure below describes the numbering sequence
of the drives in the server as well as LEDs. If you have previously configured the notification and
came to us by e
-
mail with information, we can pre
-
check that the drive needs attention.
Examples of error messages sent to ema
ATTENTION !!! When replacing the drive, be sure to replace the drive that was identical, ie.,
The same model and size, preferably also with the same firmware. Best practices say that when
you buy server buy one or two additional drives in the event of failure.
ID = 114
SEQUENCE NUMBER = 3430
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 State change: PD =
-
:
-
:8 Previous = Failed Current = Unconfigured Bad
ID = 248
SEQUENCE NUMBER = 3429
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 Device removed Device Type: Disk Device Id: 20
ID = 112
SEQUENCE NUMBER = 3428
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 PD removed:
-
:
-
:8
ID = 114
SEQUENCE NUMBER = 3427
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 State change: PD =
-
:
-
:8 Previous = Configured
-
shielded Current = Failed
ID = 401
SEQUENCE NUMBER = 3426
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 Diagnostics failed on PD:
-
:
-
:8
ID = 368
SEQUENCE NUMBER = 3425
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 Power state change failed on PD =
-
:
-
:8 Previous = On Current = Powersave
ID = 251
SEQUENCE NUMBER = 3424
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 VD is now DEGRADED VD 0
ID = 81
SEQUENCE NUMBER = 3423
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 State change on VD: 0 Previous = Optimal Current = Degraded
ID = 114
SEQUENCE NUMBER = 3422
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 State change: PD =
-
:
-
:8 Previous = Online Current = Configured
-
shielded
ID = 87
SEQUENCE NUMBER = 3421
TIME = 23
-
02
-
2015 08:16:50
LOCALIZED MESSAGE = Controller ID: 0 PD Error:
-
:
-
:8 ( Critical 244)
ID = 268
SEQUENCE NUMBER = 3420
TIME = 23
-
02
-
2015 08:16:49
LOCALIZED MESSAGE = Controller ID: 0 PD Reset: PD =
-
:
-
:8, Critical = 3, Path = 0x50030480015F2334
Information about the fact that the
disk 8 has a problem.
0
1
2
5
4
3
7
8
9
10
11
LED indicator hard disk bays job and working.
LED indicator drive failure.
6