4.1.

 

MODEL DC80R GENERAL SPECIFICATIONS 

Maximum voltage allowed between any terminal and earth ground or between the 

two input terminals: ............................................................................................ 30 V 
Resolution: ................................................. RTD 0.1 °C / °F; Resistance 0.01 / 0.1 Ω 
Storage temperature: ........................................................................ -40 °C ~ 60 °C 
Operating temperature: ..................................................................... -10 °C ~ 55 °C 
Operating altitude: ................................................................. 3000 meters maximum 
Temperature coefficient: ................ ±0.01 % / °C (0 °C ~ 18 °C and 28 °C ~ 50 °C) 
Relative humidity: ............................................................................ 95 % up to 30 °C 

 ....................................................................................................................... 75 % up to 40 °C 

 ....................................................................................................................... 45 % up to 50 °C 

 ........................................................................................................ 35 % up to 55 °C 
Shock:........................................................................... Random 2 g, 5 Hz to 500 Hz 
Safety: ............................................................................................ 1 meter drop test 
Power requirements: ...............................................................6 x AAA 1.5 V Battery 
Size:................................................................................. 205 mm x 98 mm x 46 mm 
Weight: ............................................................................. 472 g (including batteries) 

 
 
 
 
 
 
 

4.2.

 

MODEL DC80R FRONT PANEL 

The keypad and display functions are shown below: 

 4-wire input terminal (not used 

for output) 

 2-wire input / output terminal 
 2-wire input / output terminal 
 3-wire input terminal (not used 

for output) 

 Power ON / OFF switch 
 RTD type selection key 
 °C / °F selection key 
 INPUT/OUTPUT selection key  
 Fast increment key (simulation) / 

wire mode selection 

(measurement) 

 Fast decrement key (simulation) / 

wire mode selection 

(measurement) 

 Increment key  
 Decrement key  
 Low battery indication  
 INPUT mode indication  
 OUTPUT mode indication 
 Reading (measurement) value 

indication 

 Unit (°C / °F) indication 
 Input type indication 

 

Accessories included: 2 pairs of test leads and alligator clips 

Summary of Contents for DC80L

Page 1: ...L SPECIFICATIONS 9 5 2 MODEL DC80L FRONT PANEL 9 5 3 PROTECTION 10 5 4 MODEL DC80L OPERATING INSTRUCTIONS 10 6 MAINTENANCE 13 1 INTRODUCTION The Novus Calibrators series DC80 are portable instruments...

Page 2: ...e instrument for measurement or simulation 3 MODEL DC80T The MODEL DC80T is capable of measuring and generating mV and thermocouple signals The specifications shown on the tables below are valid for t...

Page 3: ...to 50 C Shock Random 2 g 5 Hz to 500 Hz Safety 1 meter drop test Power requirements 6 x AAA 1 5 V Battery Size 205 mm x 98 mm x 46 mm Weight 472 g with batteries 3 2 MODEL DC80T FRONT PANEL The keypad...

Page 4: ...large calibration errors Thermocouple or mV measurement 1 Press the power switch to turn on the calibrator 2 Press the INPUT OUTPUT key to select INPUT mode 3 Press the TC TYPE selection key to config...

Page 5: ...target instrument OHM meter of RTD meter connected to the calibrator RTD measurement and simulation specifications Mode Range Accuracy C Excitation current mA Input 4 W Input 2 W 3 W Output Pt10 385...

Page 6: ...mm x 98 mm x 46 mm Weight 472 g including batteries 4 2 MODEL DC80R FRONT PANEL The keypad and display functions are shown below 4 wire input terminal not used for output 2 wire input output terminal...

Page 7: ...ding value RTD Simulation 1 Press the power switch to turn ON the calibrator 2 Press the INPUT OUTPUT key to select OUTPUT mode 3 Press RTD mode key to select the desired RTD type 4 Press the Incremen...

Page 8: ...2 wire transmitter The following tables show the DC80L specifications functions and ranges based on a one year calibration period at ambient temperatures ranging from 18 C to 28 C Counts means units o...

Page 9: ...2 g 5 Hz to 500 Hz Safety 1 meter drop test Power requirement 6 x AAA Size 204 mm L x 99 mm W x 46 mm H Weight 460 g including batteries External power supply 9 Vdc 500 mA 5 2 MODEL DC80L FRONT PANEL...

Page 10: ...calibrator Fuse 2 is probably blown out if the calibrator reads 0 000 in mA input mode even under the presence of a current input signal 5 4 MODEL DC80L OPERATING INSTRUCTIONS DC mV and V measurements...

Page 11: ...egative test lead black to the target equipment 7 For changing the output value use the increment decrement keys and the V mV mode key until the desired value is displayed DC mA measurement a Using ex...

Page 12: ...splay 4 Plug the red test lead into the LOOP jack and the black one to the mA jack 5 Connect the test leads such that the current enters the red lead and returns to the power supply through the black...

Page 13: ...ough the black lead 7 To change the output value press the increment decrement keys and or the mA mA mode key Accessories a pair of Test Leads 6 MAINTENANCE Cleaning Periodically wipe the case with a...

Reviews: