MESSAGE 

PROBLEM DESCRIPTION 

VVVVV 

Value reading is above limits allowed for this 

sensor or signal.   

nnnnn 

Value reading is below limits allowed for this 

sensor or signal.   

------ 

Open input. No sensor or signal. 
Also displayed in the “feeder” screens in case 

no alarm is configured as “feeder”. 

SPECIAL RECOMMENDATIONS 

Should your indicator be repaired, special care must be taken with 

handling. The device must be removed from the case and immediately 

placed in an antistatic wrap, protected from extreme heat and humidity. 

CALIBRATION 

Both analog input and output are factory calibrated, and recalibration 

should not be performed by inexperienced operators. If recalibration 

of a given range is necessary, proceed as follows. 

INPUT CALIBRATION 
1.

 

Set input type to be calibrated to 4-20 mA; 

2.

 

Program 

inll

  (lower limit) and 

inkl

  (higher limit) indication 

parameters to maximum and minimum values of input type; 

3.

 

Apply to entry a signal corresponding to a known indication and 

close to its lower limit; 

4.

 

Enter calibration cycle with correct password; 

5.

 

Access 

inl(

  parameter. With 

  and 

 

keys, have 

parameter display show applied value. Then Press 

6.

 

Apply to entry a signal corresponding to a known indication and 

close to its higher limit; 

7.

 

Access 

ink(

  parameter. With 

  and 

 

keys, have 

parameter display show applied value; 

8.

 

Press 

 

or

 

 to exit screen and activate calibration. 

OUTPUT CALIBRATION 
1.

 

Mount a millimeter in the analog control output; 

2.

 

Enter calibration cycle with correct password; 

3.

 

Select 

oUL(

 parameter. Use 

 and 

 keys so that the 

device recognizes the process of calibration of current output.  

4.

 

Read current in the millimeter and enter it in the 

oUL(

 parameter 

using 

 and 

 keys. Then press 

5.

 

In parameter 

oUx(

, use 

 and 

 keys so that the device 

recognizes the process of calibration of current output; 

6.

 

Read current in the millimeter and enter it in the 

oUx(

 parameter 

using 

 and 

 keys; 

7.

 

Press 

 

or

 

 to exit screen and activate calibration. 

SERIAL COMMUNICATION 

The indicator may be optionally supplied with a RS485 asynchronous 

serial communication interface for communicating with a supervisor 

computer (master). The indicator always operates as slave.  
Communication is always initiated by the master, which sends a 

request to the slave address with which it wants to communicate. The 

addressed slave takes control and sends a response to the master.  
The indicator takes broadcast type commands (addresses to all 

network instruments). For this type of command, the indicator does 

not send any reply or acknowledgement. 

FEATURES 

Signals compatible with RS485 standard. MODBUS (RTU) Protocol. 

2-wire connection between 1 master and up to 31 indicators (it is 

possible to address up to 247 units) in bus topology. 

Communication signals are electrically isolated from the rest of the 

indicator. 

 

Maximum connection distance: 1000 meters. 

 

Selectable speed; 8 bits of data; 1 stop bit; selectable parity (no 

parity, even or odd). 

 

Start time of response transmission: 100 ms maximum after 

receiving the command. 

ELECTRICAL CONNECTIONS: RS485 INTERFACE 

RS485 signals are: 

D1 

D+ 

Bi-directional data line 

Terminal 25 

D0 

 

D- 

Reverse bi-directional data 

line 

Terminal 26 

Optional connection that 

improves communication 

performance. 

Terminal 27 

GND 

CONFIGURATION OF SERIAL COMMUNICATION PARAMETERS 

Two parameters must be configured for serial use: 

Baud

:   Communication speed. 

Prty

:   Communication parity. 

Addr

:   Communication address of indicator.  

REDUCED REGISTERS TABLE FOR 

SERIAL COMMUNICATION 

Communication Protocol 

Slave MODBUS RTU protocol supported. All configurable 

parameters of the indicator may be read and/or written through serial 

communication. Writing on registers in broadcast mode using the 

address 

0

 is also allowed. 

The following Modbus commands are available: 
 

03 - Read Holding Register    06 - Preset Single Register 

  05 - Force Single Coil      16 - Preset Multiple Register 

Holding Registers Table 

The following are the most commonly used registers. For further 

information, refer to the 

Table of Registers for Serial 

Communication

 available for download on the flow indicator website 

at 

www.novusautomation.com

The registers below are read-only. The ones that are available in a 

floating point format require two registers for being 32-bit values. 

Address  Parameter 

Register Description 

0000  

and  

0001 

Instantaneous 

flow rate 

Instantaneous flow value in floating 

point (IEEE-754). 

0002  

and  

0003 

Totalized Flow  Flow totalization value in floating 

point (IEEE-754). 

0004  

and  

0005 

Non-resettable 

Totalized Flow 

Grand total flow value in floating point 

(IEEE-754). 

0013  

to  

0016 

Totalized Flow 

Flow  totalization value in integer 

format (with signal) of 64 bits. The 

most significant part is in the first 

register. 

0017  

to  

0020 

Non-resettable 

Totalized Flow 

Grand total flow value in integer 

format (with signal) of 64 bits. The 

most  significant part is in the first 

register. 

Summary of Contents for 81500FT020

Page 1: ...ization will continue even if the input rate is below the minimum rate required Instantaneous flow rate indication will be zero whenever there is a time lapse of 10 seconds without input variation In...

Page 2: ...utput frequency has hardware limitation See Specifications Check the Specifications ALARMS The indicator s basic version has 2 alarm outputs with the option of up to 4 alarms Whenever an alarm is on a...

Page 3: ...feeder alarm will be activated If the process was stopped all counters will keep their values and the process will remain stopped until it is activated either by the key or the digital input MANUAL OP...

Page 4: ...value being modified Press while holding Available only for some parameters Change a parameter Press or to select the next option or in the case of a numerical value to increase or decrease the value...

Page 5: ...Table 5 Key f Key Function Selection of key function See Table 6 d 1n F Digital Input Function Selection of digital input function See Table 6 reset Reset Resets totalizer Bat rst Feeder Batch Reset...

Page 6: ...f the 4 20 mA input is enabled The YES option applies quadratic function on the input signal within the limits programmed in inLL and inkL Table 7 Input setup cycle keys SELECTION OF FLOW INPUT TYPE S...

Page 7: ...nt close to 20 mA will be applied Measure current in mA and enter it on this screen rstr Restore Restores factory calibration Pa x Password Change Changes user password Prot Protection Protection leve...

Page 8: ...control and sends a response to the master The indicator takes broadcast type commands addresses to all network instruments For this type of command the indicator does not send any reply or acknowledg...

Page 9: ...Isolation 250 Vrms Pulse Maximum frequency 100 Hz Voltage 0 to 30 Vdc Maximum current 15 mA Isolation 250 Vrms OUTPUT RELAYS ALM1 and ALM2 SPDT 3 A 240 Vac 3 A 30 Vdc resisitive ALM3 and ALM4 SPST NA...

Reviews: