EN
AFP 101
15
7. Start-up and operation
7.1 Preparing the AFP 101
Warning: Damage is caused to unit by not locking the retaining pin fully.
►
Press in retaining pin to the stop and turn 180° to the rear.
7.2 Operation at temperatures below -10°C
•
Insert press jaws
•
Perform a few dry runs with the AFP 101.
•
The tool is ready for operation.
7.3 Press tool and rechargeable battery
Notes on the rechargeable battery
Note: The AFP 101 press tool must only be operated with 9.6 V rechargeable batteries. The
9.6 V rechargeable battery must only be used in the appropriate press tools.
Behaviour of press tool when batteries are almost discharged:
If the battery charge diminishes, the press tool requires significantly more time for the pressing cycle.
The rechargeable battery should be replaced or recharged as soon as possible.