background image

 

 

Version: 0.1 

Date: 28.04.2009 

Page: 2 / 2 

 

                                                                               

 

We reserve the right to alter technical specification. 

 

 

 

 

Checking the function of the safety valves 

  Press "Lift" button and raise the platform completely. 

  Swing out the lip completely and let the platform sink unit the lip rests on the testing 

device (or an appropriate support). 

  Put testing weight (min. 10% of the load capacity, e.g. min. 600kg for capacity 

60kN) on centre of the platform. 

  Release the testing device respect. Remove the support in one go. 

  After a sink distance of max. 100mm (measured at the edge of the platform) both lift 

cylinders must lock. If one cylinder does not lock, repeat the test. If the cylinder does 
not lock once again, it has to be replaced. 

 
Hydraulic schedule:

 

 

60 µm

A

C1

C2

G ¼

G ¼

G ¼

Ø1,5

DV1

V1

V2

M

DB1

80-250 bar
p = 140 bar

Q=3,7l/min (140bar)
Pmax=230bar

E-Motor : 230/400V, 50Hz
0,75 kW ; S3-20%ED

Ø1,1

24V DC
100% ED
33 Ohm

V3

60-170 bar
p=120 bar

V4

G ¼

 

 

 

Reviews: