Version: 0.1
Date: 28.04.2009
Page: 2 / 2
We reserve the right to alter technical specification.
4
Checking the function of the safety valves
•
Press "Lift" button and raise the platform completely.
•
Swing out the lip completely and let the platform sink unit the lip rests on the testing
device (or an appropriate support).
•
Put testing weight (min. 10% of the load capacity, e.g. min. 600kg for capacity
60kN) on centre of the platform.
•
Release the testing device respect. Remove the support in one go.
•
After a sink distance of max. 100mm (measured at the edge of the platform) both lift
cylinders must lock. If one cylinder does not lock, repeat the test. If the cylinder does
not lock once again, it has to be replaced.
Hydraulic schedule:
60 µm
A
C1
C2
G ¼
G ¼
G ¼
Ø1,5
DV1
V1
V2
M
DB1
80-250 bar
p = 140 bar
Q=3,7l/min (140bar)
Pmax=230bar
E-Motor : 230/400V, 50Hz
0,75 kW ; S3-20%ED
Ø1,1
24V DC
100% ED
33 Ohm
V3
60-170 bar
p=120 bar
V4
G ¼