NOVO 485HE Owner'S Manual Download Page 42

42

6(77,1*6

83

'2:1

0$18$/

5(*(1

Main Valve Settings

Meter Ratio

METER RATIO AFTER MAR 20,2018  - 5.68 

METER RATIO BEFORE MAR 20,2018  - 8.00

Service Delay

3.0

Backwash Delay

7.0

Brine Delay

4.0

Rinse Delay

5.0

Refill Delay

4.0

VALVE MODE

Softener UF

BACKWASH

4 Minutes

BRINE

90 Minutes

UNIT SIZE

1.00 CF

RINSE

7 Minutes

PROGRAMMING 

COMPLETE

Press 

SET/Regen

 Key  

Press 

SET/Regen

 Key   

MASTER PROGRAMMING

Press 

Up 

and

 Down

 Button for 5 seconds

Press 

MANUAL REGEN

 Button and and change value using 

Up 

and

 Down

 Buttons

 

  

Key Pad Setting

SETTINGS

  

This function is to enter the basic set up information required at the   

 

  time of installation. 

MANUAL 

This function is to initiate an immediate or delayed manual  

REGEN

 regeneration.

  

DOWN /  

Increase or decrease the value of the settings while in the  

UP

 

programming mode.

 

  

SOFTENER UF (UP FLOW)

 

This mode is for the operation of an up flow regenerating softener. The amount of salt 

used each regeneration is proportional to the capacity remaining in the system. A preset 

amount of brine (Default is 70%) is prepared after a normal regeneration. Just before a 

regeneration is scheduled, fresh water is added to the brine tank to “top off” the already 

prepared 70% of brine. The total amount of brine used to regenerate the system is 

proportional to the capacity remaining.
I.e. If the system has 10% capacity remaining, then only 90% of the salt dosage is 

needed to restore ca-pacity to 100%. 70% of the brine is already prepared (and fully 

saturated) so 20% is added so that the total of 90% is prepared.

When a standard regeneration is started, the valve will move first to the refill position 

to add water to the brine tank. The amount of water added is equal to the calculated 

refill time for the salt dosage X Brine Tank Refill%. The valve then will return to service 

for the amount of Brine Make Time. When this is com-plete the valve will move to the 

Brine position.
The regeneration sequence is 1. BRINE MAKE (REFILL), 2. BRINE, 3. BACKWASH, 4 RINSE, 

5. RE-FILL. 

 

LANGUAGE

 

Current available language is English. 

 

UNITS

 

Current unit of measure is gallons. Metric units may become available at a later date. 

 

EFFICIENCY & CAPACITY SETTINGS

 

There are 3 settings to choose in Settings. High Efficiency, Standard Capacity, and Iron & 

Manganese. The values for these settings are set in the Factory Options and are used to 

calculate the system capacity and refill time. 

 

REFILL

 

This value should match the BLFC flow washer. It is used to calculate the refill time. 

 

BRINE MAKE TIME

 

This value is the time allowed for the salt to dissolve in the water to create the brine 

solution. The value is the amount of time ahead of the scheduled regeneration time that 

the water will be added to “top off” the brine already prepared in the brine tank. 

 

BRINE PRE-FILL%

 

This is the percentage of the water that will be added to the brine tank after a regener-

ation. The default is 70%. The remaining amount of water will be added just prior to the 

regeneration and will be proportional to the amount of capacity left in the system. 

 

DAILY RESERVE

 

This value is used to calculate the reserve capacity. Reserve Capacity = No. People x DAILY 

RESERVE. 

 

DAY OVERIDE

This setting can be used to add number of days to over ride the meter. As an example if the 

setting is 5, the system will regenerate after 5 days even if there is still gallons capacity 

remaining. OFF will cancel this feature. 

 

RINSE OVERIDE

 

This setting can be used to skip the RINSE cycle. As an example if the setting is 10, the 

system will skip 10 rinse. OFF will cancel this feature. 

 

BW OVERIDE

 

This setting can be used to skip the back wash cycle. As an example if the setting is 10, the 

system will skip 10 back wash cycles. The setting will only work if the WATER TYPE is set to 

CITY for clean water applications. 

 

FORCED REGEN

When set to ON, the system will start a forced regeneration when the remaining capacity 

reaches 3%. The regeneration consists of 8 minutes of Brine and 12 minutes of Rinse. 

The 20 minutes regeneration will restore up to 33% of the system capacity. At the next 

regeneration time (2:00 AM), the system will automat-ically perform a standard regenera-

tion to restore ca-pacity to 100%. 

 

VACATION MODE

When set to ON, the system will perform a 10 minute back wash and 10 minute rinse if 

there is no water flow detected after 7 days. The regeneration will occur at the scheduled 

REGEN TIME.

Summary of Contents for 485HE

Page 1: ...s before August 2019 Upflow Softener Manual 1 Page 22 of this manual contains important maintenance procedures for the continued proper operation of your unit These MUST be performed regularly for you...

Page 2: ...NCE INSTRUCTIONS AND SCHEDULE 24 RES UP FEEDER INSTALLATION INSTRUCTIONS OPTIONAL 25 TROUBLE SHOOTING GUIDE 27 REPLACEMENT INSPECTION AND REPLACEMENT OF PISTON ASSEMBLY AND SEAL AND SPACER KIT 29 CLEA...

Page 3: ...tified lubricant to all seals It is not uncommon for sediment precipitated iron or hardness to be present in water supplies Precipitated minerals or sediments can cause damage to the seals and piston...

Page 4: ...sing a softener to remove both hardness and dissolved iron it is important that it regenerates more frequently than ordinarily would be calculated for hardness removal alone Although many factors and...

Page 5: ...F and 110 F 4 C 43 C Working Pressure This water softener must be operated on pressures between 30 psi to 125 psi If the water pressure is higher than 125 PSI use a pressure reducing valve in the wat...

Page 6: ...e box For Models 75 100 150 200 you will expect the following 1 Control Valve 2 Tank 3 Parts Box 4 Owners Manual 5 Drain Hose Clamp Not included in some brands 6 Brine Tank Assembly UNPACKING INSPECTI...

Page 7: ...mbly 18280 Upper Basket 2 Parts Box 60090003 2X 1 Straight Adapter 60010006 Bypass Tool 60010026 O Rings Attached 60090010 2 X 3 4 Elbow Adapter 60010052 Transformer 92360 Grease Packet There are 8 Re...

Page 8: ...installation and tightened if necessary UNPACKING INSPECTION OF CABINET MODEL 1 Cabinet with Valve attached 2 Parts Box 3 Drain Line and Hose Clamp 18280 Upper Basket 2 Parts Box 60090003 2X 1 Straig...

Page 9: ...in the float assembly elbow and hand tighten the nut In many cases the brine line already come installed from the factory Leave the other end of the brine line tube inside the brine tank f For install...

Page 10: ...reValve 22018421Y M 4 L 0001 PART NUMBER YEAR 2016 MONTH APR DAY of MONTH 21 BATCH NUMBER Valve Serial CHECK VALVE TYPE AND VALVE SERIAL Check to make sure Valve Type is Upflow UF left Sticker shown b...

Page 11: ...uired for Installation NOTE We recommend installation only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local plumbing codes s...

Page 12: ...9003 a Temporarily plug the open end at the top of the riser distribution tube with tape b Ensure the bottom of the riser tube remains seated in the depression at the bottom of the tank Fill tank one...

Page 13: ...ment and will void the factory warranty 8 Allow sufficient space around the unit for easy servicing 9 Keep the conditioner out of direct sunlight The sun s heat may soften and distort plastic parts 2...

Page 14: ...his is why the automatic regeneration is set for sometime during the night and manual regenerations should be performed when little or no water will be used in the household See STARTUP PROGRAMMING pa...

Page 15: ...alve must be done before connecting any piping to the valve Always leave at least 6 152 mm between the valve and joints when soldering pipes that are connected to the valve Failure to do this could ca...

Page 16: ...d Soft Water To Outside Faucet In Out Outlet Inlet NOTE Check local plumbing codes in regards to requirements for use of Check Valve or back flow prevention or vacuum breaker CAUTION Never insert drai...

Page 17: ...utlet BRINETANK MODEL Water to be Added at theTime of Installation BTR 100 18 1 x 34 7 2 5 US Gallons BTR 145 20 3 x 37 4 3 25 US Gallons BTR 200 23 0 x 40 5 5 5 US Gallons STEP 2 AddWater to BrineTan...

Page 18: ...s SETTINGS once to highlight the current month 11 Press SETTINGS once to highlight DAY 6 Now press UP or DOWN key to change the minute value to current time 8 Now press UP or DOWN key to change the AM...

Page 19: ...____ Enterthisamount 6 77 1 6 83 2 1 0 18 5 1 6 77 1 6 83 2 1 0 18 5 1 6 77 1 6 83 2 1 0 18 5 1 DAY 19 SET HARDNESS 20 GRAINS SET HARDNESS 15 GRAINS 13 Press SETTINGS once to highlight value 12 Now pr...

Page 20: ...ODE 6 77 1 6 83 2 1 0 18 5 1 6 77 1 6 83 2 1 0 18 5 1 6 77 1 6 83 2 1 0 18 5 1 AUG 30 2019 12 15AM VACATION MODE OFF 1 To setVACATION MODE press hold SETTINGS and MANUAL REGEN until you hear a beep 2...

Page 21: ...xposed to both iron and hardness for a long period of time replacement of the heater tank maybe the only practical solution to prevent continued staining originating from this source After completing...

Page 22: ...ould always be followed up by allowing the unit to use up any remaining salt and then thor oughly cleaning out the brine tank Allow four hours to produce a brine solution then manually regenerate the...

Page 23: ...Separately The 12 cc feeder Part 33010 is for conditioners up to 64 000 grains 2 ft3 of resin The 30 cc feeder Part 33018 is for larger conditioners over 64 000 grains Pro Res Care Chemicals Item 451...

Page 24: ...ne Well lid 6 Take off the cover of the Res care bottle Insert the wick making sure it touches the bottom of the bottle Insert the other end of the tube completely into the hole in the brine well cap...

Page 25: ...er source this water softener is being applied on is not municipal water and contains up to 2 0 mg l ppm of ferrous ClearWater iron and or up to 75 mg l ppm of manganese the enclosed Problem Water Inj...

Page 26: ...or restrictions in the drain line See page 33 Using too much salt or more salt than expected Check programming is the unit set properly for salt efficiency is the programming correct for hardness and...

Page 27: ...eter by moving a fridge magnet or similar magnet across it rapidly for a few seconds you should be able to see the gallons change Be sure there is no debris caught in the the turbine If the meter cabl...

Page 28: ...6 Replace the piston assembly and reverse following steps in this section Remove 3 X Screws Plate Seal and Spacer Brine Valve Assembly Piston Assembly 4 INSPECTION AND REPLACEMENT OF PISTON ASSEMBLY A...

Page 29: ...coupling adapter from the bypass 4 Remove the meter and meter support from the bypass and replace 1 2 REPLACE MOTOR 1 Pull the powerhead cover 2 Remove all connections from the circuit board 3 Remove...

Page 30: ...lief with pliers Replace the old cable with the new Cable 60095101 Bypass comes with Meter and Grey Meter Cable NOTE Water to the household needs to be turned off and pressure relieved before Step 2 C...

Page 31: ...Line Elbow Clip Drain Line Elbow Drain washer REPLACE DRAIN LINE FLOW CONTROL REPLACE BRINE LINE FLOW CONTROL 1 Pull the drain line clip and remove the drain line elbow and washer 2 Clean replace drai...

Page 32: ...ll automatically build in the conditioner 3 Check for leaks at all sealed areas Check Drain seal with the control in the backwash position 4 Plug electrical cord into outlet 5 Set Time of Day and cycl...

Page 33: ...k 75 8 x 44 25020051 50010019 10010060 95600 30020006 100 9 x 48 25020052 50010006 95601 30020006 150 10 x 54 25020053 50010005 95606 30020006 200 12 x 52 25010058 50010005 95609 30020010 250 13 x 54...

Page 34: ...wn GRID 55010013 For BTR 100 55010036 For BTR145 55010037 For BTR 200 FLOAT ASSY 55010023 BTR100 55010054 BTR145 55010033 BTR200 Tube Stiffener Part 10332 03257 17 3 6 1685 7 77 78 67 1 5 6 16 57 172...

Page 35: ...isplay After Aug 15 2019 1 14 92393 Bnt85 Motor 1 13 60095658 Motor Pin 1 12 60010673 Screw ST2 9 10 8 11 60021982 Main Pcb DF After Aug 15 2019 60021981 Main Pcb UF After Aug 15 2019 10 60010574 Scre...

Page 36: ...ly 60032 Item s For All Injector Assemblies and Brine Line and Drain Line Washers Part Part Description 60010110 BLFC BUTTON 2 0 3GPM A32 60010082 BLFC BUTTON 2 0 7GPM A32 60010128 BLFC BUTTON 0 2GPM...

Page 37: ...2 60010740 Bypass Shaft Inlet 1 21 60010740 Bypass Shaft Outlet 1 20 60095614 O ring 30 2 65 2 19 60010740 Shaft Seal 2 18 60010069 Plug Clip Red 2 17 60010740 Shaft Clip Red 2 16 60010209 Bypass Plug...

Page 38: ...d 1 11 Transparent Back Cover 1 No Part Description Qty 10 Screw 2 9 6 5 10 9 302171 Drain Line Clamp 1 8 60095097 1 Canature BypassValve C W Meter 1 7 10010061 ControlValve Assembly CS5 1 6 18280 Top...

Page 39: ...39 Cabinet Model B Twin Tank Model A A B A B 0844 49 98 8 0948 53 98 9 1054 59 98 10 1252 57 98 12 1354 59 98 13 1465 70 98 14 75C 100C A 43 31 43 31 B 16 54 16 54 SYSTEM DIMENSIONS...

Page 40: ...t tank body salt tank lid 7 3 20 35 1028 186 40 5 517 175 225 275 brine well and brine valve salt grid system 585 23 BTR 200l label BTR200 Model LiquidVolume Tank Dimensions inches Salt Capacity US Ga...

Page 41: ...TION DO NOT CHANGE LEVEL 2 SETTINGSWITHOUT CONSULTING A CANATUREWATERGROUPTECHNICIAN 1 877 288 9888 Wrongly changing the settings can result in malfunction of the unit When the Level 2 Master Programm...

Page 42: ...nits may become available at a later date EFFICIENCY CAPACITY SETTINGS There are 3 settings to choose in Settings High Efficiency Standard Capacity and Iron Manganese The values for these settings are...

Page 43: ...2 GPM 0 2 GPM 0 2 GPM BRINE MAKETIME 30 MIN 30 MIN 30 MIN 30 MIN 30 MIN 30 MIN 30 MIN 30 MIN 30 MIN 30 MIN BRINE PREFILL 70 70 70 70 70 70 70 70 70 DAILY RESERVE 75 GAL 75 GAL 75 GAL 75 GAL 75 GAL 75...

Page 44: ...__________________________ ___________________________________________________________________ ___________________________________________________________________ _____________________________________...

Reviews: