PRESS SETTINGS KEY
3 SEC TO UNLOCK
AUG/30/2019
12:15AM
BACKWASH
10:00 REMAIN
1.
The display will read
“PRESS SETTINGS
KEY
3 SEC TO UNLOCK”
.
2.
After 3 seconds, the display will beep
confirming unlock.
3.
Press and hold
MANUAL REGEN
to
start Manual Regeneration process
4.
The display will read time remaining.
ALLOW TO FINISH FULL CYCLE.
6(77,1*6
83
'2:1
0$18$/
5(*(1
LAST REGEN.
JAN/01/2019
SETTINGS BUTTON
The function of this key is to
enter the level one program-
ming mode where the valve
settings can be adjusted.
MANUAL REGEN BUTTON
This button has two functions. The first is to initiate a manual
regeneration by holding the button for 3 or more seconds. The
second function is while in programming mode, pressing this key
allows the user to change the value of each setting.
UP / DOWN
These buttons are used to
increase or decrease the value
of the settings while in the
programming mode.
Key Pad Configuration
STARTUP & PROGRAMMING
The control valve is controlled with simple, user-friendly electronics displayed
on an LCD screen. When power is connected, the screen will show the following
information in sequence:
1.
Date & Time
2.
Regeneration Days (Time
interval between backwashes)
3.
Remaining Days (days left before
backwash begins)
4.
Regeneration Time (Time of day
when backwash starts)
5.
Last Regeneration Date (Last
date when system backwashed)
6.
Current Flow Rate (GPM) (flow
rate of water being currently used)
7.
Peak Flow Rate (GPM) (Max
recorded flow rate of the water)
STEP 1. Connect the Transformer to the Valve
Plug the 12-volt transformer into a 120 VAC 60 Hz outlet.
BRINE TANK MODEL
– Water to be Added at the Time of Installation:
BTR-100
(18.1” x 34.7” ) - 2.5 US Gallons
BTR-145
(20.3 x 37.4) - 3.25 US Gallons
BTR-200
(23.0” x 40.5”) - 5.5 US Gallons
STEP 2. Add Water to Brine Tank
Open the brine tank /cabinet salt lid and add water as per the info below.
Do not add salt to the brine tank at this time.
Please call Canature WaterGroup before attempting to change any Level 2 values as this can affect the performance of your
unit. (See page 41for Level 2 Programming)
STEP 3. Manually Regenerate the Valve
3a.
Open the inlet on the bypass valve slowly and allow water to enter the unit. (The outlet of the bypass should remain closed to prevent any fines or debris from entering the
plumbing system. Allow all air to escape from the unit before turning the water on fully then allow water to run until the drain water appears to be clear of any fines or
color.
3b.
Plug in the valve. Allow the valve to continue its cycles until complete and back in service. Allow the valve to stay in each position for 2 - 3 minutes to purge air from the
system and the valve. Failure to properly purge the system may result in unsatisfactory performance. This process can be performed more than once if necessary to purge
air and color or fines from the system before finishing start up. Once the system is purged properly you can open the outlet of the bypass valve. Because your plumbing
system has been disturbed it is advisable to remove screens from faucets and flush all lines until clear.
See Plumbing System Clean-Up on page 23
.
STEP 4. PROGRAMMING YOUR CONDITIONER
This unit is factory set for the correct size, you are required to program the date, the time, the number of people in the home and the correct hardness setting. Please review
Compensated Hardness Calculation
(See page 22) before entering the hardness number from your water analysis.