Novis APMBL-L01 User Manual Download Page 4

4

User Guide 

BetterLiving

Safety Precautions

The purpose of the following safety precautions 
are to direct attention to possible dangers. The 
safety symbols and their explanations require 
careful attention and understanding. 

The safety warnings by themselves do not 
eliminate any danger. The instructions or 
warnings they give are not substitutes for 
proper accident prevention measures.

For your own safety and the safety of equipment, 
always take the following precautions.

General Safety Precautions

  Read all instructions before using this 

medical device

  This system must be used on top of an 

appropriate sized bed frame and the 
appropriate operating environment as 
stated in this manual.

  Do not place the overlay directly on the 

bed frame; designed for use on mattress.

  Before commencing set up or installation, 

ensure the power is switched off 
and disconnect the power cord from 
the control unit. Novis Healthcare 
recommends using the cord retention 
loops on either side of the mattress 
replacement where possible and  
attaching it to an electrical outlet  
by the head of the bed.

  Minimise layers between patient and 

mattress and secure bed sheets loosely 
so as not to affect the alternating cell 
movement. As part of a sensible pressure 
injury prevention strategy, avoid wearing 
clothing that may cause areas of localised 
damage due to creases, seams, objects in 
pockets, etc.

  Never use sharp objects or electrically 

heated blankets on or under the system.

  Product top cover may present a 

suffocation risk. It is the responsibility of 
the caregiver to ensure that the patient can 
use this product safely.

  Avoid blocking the air intakes of the 

control unit, located at the rear of the unit. 
Do not place items such as blankets over 
the control unit.

  Bed frames used with the systems can 

vary greatly depending on the specific 
healthcare setting (ie hospitals, aged care, 
home care, etc). It is the responsibility 
of the caregiver to take the necessary 
precautions to ensure the safety of the 
patient. This includes, but is not limited to, 
the appropriate use of side rails to prevent 
falls.

  Only the control unit and mattress 

combination as indicated by Novis 
Healthcare should be used, otherwise the 
correct function of the product cannot be 
guaranteed.

 

User Capacity 

  The maximum recommended patient 

weight is 180 kilograms for the Mattress 
Replacement and 150 kilograms for the 
Mattress Overlay. 

  The minimum recommended patient 

weight is 40 kilograms for both the Mattress 
Replacement and Mattress Overlay.

  Do not exceed this safe working load or 

you risk injury to the patient or carer and 
damage to the product.

Summary of Contents for APMBL-L01

Page 1: ...MATTRESS OVERLAY AlternatingMattressReplacement Overlay U S E R G U I D E MATTRESS REPLACEMENT...

Page 2: ...sional Ifyouhaveanyquestions pleasecontactNovis Healthcareon1300738885 NovisHealthcarehasapolicyofcontinuous productimprovementandreservesthe righttoamendspecificationspresentedin thisguide Informatio...

Page 3: ...osesandCPRrelease Controlunit Powercord Userguide Carrybag Itisrecommendedthatallpacking materialsandmanualsbekeptinthecarry bagprovided foreaseofstorageand or transport Intended Use Thepreventionandt...

Page 4: ...ble pressure injury prevention strategy avoid wearing clothing that may cause areas of localised damage due to creases seams objects in pockets etc Never use sharp objects or electrically heated blank...

Page 5: ...oxygenornitrousoxide Donotuseinthepresenceofsmoking materialsoropenflame airflowingthroughthemattresswillsupport combustion Donotopenthecontrolunit riskof electricalshock Referservicingtoqualified ser...

Page 6: ...a which may risk damage to the mattress replacement BedBase UmbilicalCord FootSymbol Attachtothebedbysecuringtheadjustable straps locatedontheundersideofthemattress baseundereachbedend Onaprofilingbed...

Page 7: ...ddingfromthemattressand placethemattressoverlayontheexisting mattress orsuitablefoamunderlay Printedtopcoverfacingupwardsand umbilicalhosetowardsthebaseofthebed CheckCPRsealingvalveisclosed the turnin...

Page 8: ...clickasconfirmation theconnectorislockedinplace Straighten any twists in the umbilical air hoses Ensure the umbilical air hose is not trapped between the mattress and bed Feedpowercordthroughthecordre...

Page 9: ...lie a person or any weight on the mattress during initial inflation Wheninitialinflationiscomplete the PressureSettingandMaxInflateindicators willextinguish toindicatethesystemis readyforuse Thesyste...

Page 10: ...nderneaththepatientandfeelforadeflatedcellunderthepatient slower spine Theinnerstaticcellwillremaininflated howeveryourhandshouldeasilyslidebetween patientandbase Ifyourhandcanpassunderthepatient then...

Page 11: ...dicatethemodecurrentlyactive SeeModeonpage12formoredetails D Power Pressandholdforaminimumofthreeseconds toturnsystempoweronandoff Green light poweron E Alarm Mute Turnsaudiblealarmofftemporarily Pres...

Page 12: ...to ensureallaircellsareinflated Beforemovingthemattress ensurethecontrol unitisswitchedoffanddisconnectedfrom mainspower Disconnecttheumbilicalairhose fromthecontrolunitbyunpluggingthequick releasecon...

Page 13: ...flateallcells Pressthereleasebuttonsontheumbilicalcord connectorstoreleasetheairhoses Onceairhasbeenreleasedfromthesystem detachthemattressfromthebed Rollthe mattressfromheadendtofootendtoremove addit...

Page 14: ...rol It is recommended that the system is cleaned every two weeks if in constant use Base Cleaning Swabthemattressbaseandcellswithasolutionofsodiumhypochloriteorsimilar upto10 000 ppmavailablechlorine...

Page 15: ...moisture Asoftbristlednylonbrushcanbeusedtogentlycleancrevices Ensure the control unit is disconnected from mains power before cleaning Donotspraydisinfectantdirectlyontothecontrolunit orimmersetheun...

Page 16: ...nen dust Replace withnewfilterifneeded Ensuretheaircellsarefreeofdamageorleaks Forfastermattressreinflationoncetheairleakhasbeenclosed pressMAXINFLATEandwaituntil thePressureLossindicatorextinguishes...

Page 17: ...propriateaccordingthelegislation Please beenvironmentallyresponsibleandcontact yourlocalauthorityonavailableoptionsto recycle thisproductatitsendoflife Service Life Theexpectedservicelifeofacontroluni...

Page 18: ...m canbeestimatedusingtheequationapplicabletothefrequencyofthetransmitter wherepisthemaximumoutputpower ratingofthetransmitterinwatts W accordingtothetransmittermanufacturer NOTE1 At 80 MHz and 800 MH...

Page 19: ...0 15MHz 80MHz PortableandmobileRFcommunications equipment shouldbeusednoclosertoanypartofthecontrolunit includingcables thantherecommendedseparation distancecalculatedfromtheequationapplicabletothe fr...

Page 20: ...B 217Hz 0 2 0 3 9 9 745 780 810 800 960 GSM800 900 TETRA800 iDEN 820 CDMA850 LTE Band5 Pulse modulationB 18Hz 2 0 3 28 28 870 930 1 720 1700 1990 GSM1800 CDMA 1900 GSM1900 DECT LTEBand1 3 4 25 UMTS Pu...

Page 21: ...z MAXIMUM CURRENT 0 2 to 0 1A FUSE RATING T2AL250V MIN MAX PRESSURE 20 60mmHg 6mmHg PROTECTION TYPE ClassIITypeBF INGRESS PROTECTION RATING IP21 HEIGHT x WIDTH x DEPTH 195 x 265 x 120mm WEIGHT 2kg MAT...

Page 22: ...ed toitspremisesoroneofitsAuthorisedService Agentsinpersonorfreightprepaidbyyou Noviswillundertakeatitsoption torepairor replace freeofcharge eachproductorpart thereofontheconditionthat Theproductfoun...

Page 23: ...ndthefailure doesnotamounttoamajorfailure Toobtain compensation youwillneedtoprovided documentaryevidenceofthelossordamage sufferedanddocumentaryevidencethatsuch lossordamagewasareasonableforeseeable...

Reviews: