1. Sensor Position
2. Dispense process
3. Labels with
non-rectangular
shape
To switch the unit
on or off
Material that dispenses a number of labels at the same time.
When several labels are
side by side, the position
mark must run over a
label, but be as close to
the centre of the material
as possible.
The label under the
sensor must be remo-
ved last.
After removing the last
label the next row is
automatically dispensed
The sensor must be positioned exactly for all labels with a non-rectangular
shape (round, oval, triangular...).
The highest point of the label must be between the small rolls of the sensor.
To switch the unit on or off simply connect it to, or disconnect it from, the
mains socket. It is not essential to switch the unit off when not in use.
Socket must be freely accessible.
The device is to be operated only with power supplies which comply with
the requirements of safety extra low voltage (SELV) according to DIN, VDE
0805.
The cable can be fixed by a clamp at the housing.
2.
3.
1.
ce
nt
er
o
f m
at
er
ia
l
O p e r a t i n g