04/16 Rev. 06
USER MANUAL
Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
7
Settings in the parameter menu
Further settings for 64-xx Dispenser see user manual 64-xx, topic section „Setup“,
chapter
Settings for application of ALX 92x with applicator see service manual ALX 92x,
topic section „Applicator Interface“, chapter
Setting
Interface
Printer
Parameter
Value
Accept start si-
gnals
--
All
SYSTEM PARAMETER > Exter-
nal signal
Singlestart
Signal source
Singlestart
input
64-xx
--
a
--
64-xx Dispenser,
AP 5.4 Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start
source
Foot switch
AP 5.4, AP 5.6, AP 7.t
--
--
Disp. edge
light barrier
64-xx Dispenser,
AP 5.4Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start
source
Light barrier
USI
64-xx Dispenser
DISPENSER PARA > Start
source
USI interface
64-xx, ALX 92x, ALX 73x
--
--
I/O
AP 5.4, AP 5.6, AP 7.t
--
--
AI
ALX 92x, ALX 73x
--
--
Signal flange
Singlestart
input
64-xx, AP 5.4, AP 7.t,
AP 5.4Gen II, AP 5.6
SYSTEM PARAMETER > Start
print mode
„Pulse rising“
USI
64-xx, ALX 92x
DP INTERFACE > Start print
mode
„Pulse rising“
I/O
AP 5.4, AP 5.6, AP 7.t
I/O BOARD >
Start print mode
„Pulse rising“
AI
ALX 92x, ALX 73x
APPLICATOR PARA > Start
print mode
„Pulse rising“
Start delay
Singlestart
input
AP 5.4Gen II Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start off-
set
Enter distance
between start
sensor and dis-
pensing edge
USI
64-xx, ALX 92x, ALX 73x
DP INTERFACE > Start delay
I/O
AP 5.4Gen II Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start off-
set
AI
ALX 92x, ALX 73x
APPLICATOR PARA > Start de-
lay
[Tab. 5] Overview on the most important settings for start signal application (Firmware versions 3.52/6.52/7.52).
a) „--“ = No setting required.
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...