940
GroupWise 7 Administration Guide
no
vd
ocx (
e
n)
1
1
Decemb
er
2
007
Modifying WebAccess Agent Log Settings through Startup Switches
Startup switches override any log settings you specified through ConsoleOne. See
“Modifying
WebAccess Agent Log Settings in ConsoleOne” on page 939
.
For information about startup switches that can be used to modify log settings, see
Section 57,
“Using WebAccess Startup Switches,” on page 945
.
Modifying WebAccess Agent Log Settings through the WebAccess Agent Server
Console
“Modifying Log Settings through the NetWare Agent Server Console” on page 940
“Modifying Log Settings through the Windows WebAccess Agent Server Console” on
page 940
“Modifying Log Settings through the Linux WebAccess Agent Server Console” on page 940
Modifying Log Settings through the NetWare Agent Server Console
You can use the NetWare WebAccess Agent server console to modify the following log settings:
Changes you make to log settings at the console apply only to the current session. When you restart
the WebAccess Agent, the log settings are reset to the settings specified in ConsoleOne or the startup
switches. See
“Modifying WebAccess Agent Log Settings in ConsoleOne” on page 939
and
“Modifying WebAccess Agent Log Settings through Startup Switches” on page 940
.
To modify the log settings:
1
At the NetWare WebAccess Agent’s server console, press F10, select
Logging Options
, then set
the log settings as needed:
2
Press Esc to save the information.
Modifying Log Settings through the Windows WebAccess Agent Server Console
You can use the Windows WebAccess Agent’s console to modify the logging level. All other log
settings must be modified through ConsoleOne or startup switches. See
“Modifying WebAccess
Agent Log Settings in ConsoleOne” on page 939
and
“Modifying WebAccess Agent Log Settings
through Startup Switches” on page 940
.
Changes you make to the log level at the console apply only to the current session. When you restart
the WebAccess Agent, the log level is reset to the level specified in ConsoleOne or the startup
switches.
To modify the logging level:
1
In the NetWare WebAccess Agent’s console (the DOS window), press F2 to cycle the log level
between Normal, Verbose, and Diagnostic. Each level is described below:
Modifying Log Settings through the Linux WebAccess Agent Server Console
On Linux, the WebAccess Agent server console does not include functionality to change log
settings. These settings must be modified through ConsoleOne, as described in
“Modifying
WebAccess Agent Log Settings in ConsoleOne” on page 939
or in the startup file, as described in