Ex-Power DEFENDER – Operation and Maintenance Manual
Novatio Engineering Confidential Document
3-9
3.5.2
AC Parallel Operation - Cautions and Notes
Follow the instructions included with the optional parallel operation cable assembly, before
connecting an appliance or power cord to the generator (optional equipment, provided by
Novatio). For single generator operation, the parallel operation cables must be removed.
•
Never connect or remove the parallel operation cable assembly when the
generators are running.
•
Substantial overloading that continuously lights the overload indicator (red)
may damage the generator. Marginal overloading that temporarily lights the
overload indicator (red) may shorten the service life of the generator.
•
Never connect different generator models.
•
Only use approved parallel operation cables (optional equipment, provided
by Novatio) when connecting two Ex-Power DEFENDER generators for
parallel operation.
Review the “Pre-operation – Warnings, Cautions, and Checking the Engine” information in
Section 3.2 before starting procedures in the following subsection.
3.5.3
AC Parallel Operation - Connections and Operation Procedures
1.
Connect the parallel operation cables (optional equipment shown below) between the two
Ex-Power DEFENDER generators, following the instructions supplied with the parallel
operation cables.
2.
Start the engines and make sure the output indicator (green) on each generator comes on.
Figure 3-4: Parallel Operation (Using Optional AC Parallel Cables)
3.
Plug the appliance into one of the AC receptacles. Follow the instruction provided with
the parallel operation cable assembly.
4.
Turn ON the appliance.
5.
When finished parallel operation, turn OFF the appliance.
CAUTIONS
Summary of Contents for Ex-Power DEFENDER
Page 44: ...NOTES...