78
SMART-MR10 User Manual Rev 0B
Appendix B
Commands
B.4
FRESET Clear Selected Data from NVM and Reset
This command is extended to include SMART-MR10 features. An additional target field,
userdata
(value = 10), resets only the SMART-MR10 user data NVM, thereby resetting all parameters indicated
in this document as “Stored in NVM” to factory defaults. Issuing the FRESET command with the
“target” field set to
standard
, resets the userdata NVM as well as OEMV parameters as indicated in
the
OEMV Family Firmware Reference Manual
.
If you issue the FRESET command without any parameters, it is the same as issuing a FRESET
STANDARD command.
Table 15: FRESET Target
Field
Field
Type
ASCII
Value
Binary
Value
Description
Binary
Format
Binary
Bytes
Binary
Offset
1
FRESET
header
-
-
This field contains the
command name or the
message header
depending on whether
the command is
abbreviated ASCII,
ASCII or binary,
respectively.
-
H
0
2
target
See
Data to be reset by the
receiver
Enum
4
H
Binary
ASCII
Description
0
STANDARD
Resets commands, ephemeris, and almanac (default). Also resets
all L-band related data except for subscription information.
1
COMMAND
Resets the stored commands (saved configuration)
2
GPSALMANAC
Resets the stored GPS almanac
3
GPSEPHEM
Resets the stored GPS ephemeris
4
GLOEPHEM
Resets the stored GLONASS ephemeris
5
MODEL
Resets the currently selected model
10
USERDATA
Reset SMART-MR10-only commands
11
CLKCALIBRATION
Resets the parameters entered using the CLOCKCALIBRATE
20
SBASALMANAC
Resets the stored SBAS almanac
21
LAST_POSITION
Resets the position using the last stored position
31
GLOALMANAC
Resets the stored GLONASS almanac