Novatek NACF75 Operating Instructions Manual Download Page 2

1

Typical Installations

Novaclean MMF - Specifications 

Model

Media

Flow Rates USGPM

Installation Space

Fiberglass Tank

Shipping

Description

Cu Ft

Service

Peak

Backwash

Inches - W x D x H

Size - Inches

Weight - Lbs

NMMF75

.75

4

5

4

10 x 10 x 57

8 x 47

95

NMMF10

1.0

5

7

5

11 x 11 x 58

9 x 48

145

NMMF15

1.5

7

10

7

12 x 12 x 64

10 x 54

213

NMMF20

2.0

10

12

10

14 x 14 x 62

12 x 52

265

Novaclean ACF - Specifications 

Model

Carbon

Flow Rates USGPM

Installation Space

Fiberglass Tank

Shipping

Description

Cu Ft

Service

Peak

Backwash

Inches - W x D x H

Size - Inches

Weight - Lbs

NACF75

.75

4

5

3.5

10 x 10 x 57

8 x 47

45

NACF10

1.0

5

7

5

12 x 12 x 57

10 x 47

65

NACF15

1.5

7

10

7

14 x 14 x 62

12 x 52

93

NACF20

2.0

10

12

10

16 x 16 x 60

14 x 50

105

Novaclean NF - Specifications 

Model

Media

Flow Rates USGPM

Installation Space

Fiberglass Tank

Shipping

Description

Cu Ft

Service

Peak

Backwash

Inches - W x D x H

Size - Inches

Weight - Lbs

NNF75

.75

2

3.5

3.5

10 x 10 x 57

8 x 47

75

NNF10

1.0

3

5

4

11 x 11 x 58

9 x 48

115

NNF15

1.5

5

8

5

12 x 12 x 64

10 x 54

165

NNF20

2.0

6

10

7

14 x 14 x 62

12 x 52

215

• Peak flow rates intended for intermittent use only (10 minutes or less) and are for

residential applications only. Do not use peak flow rates for commercial
applications.

• At the stated flow rates, the pressure drop through these devices will not exceed 15

psig.

• For satisfactory operation, the pumping rate of the well system must equal or

exceed indicated backwash flow rate.

• Maximum Water Temperature = 110

o

F (43

o

C)

• Maximum Operating Pressure = 100 PSIG (689 kPa)
• Pipe Size = 3/4”
• Voltage = 110V Standard
• The manufacturer reserves the right to make product improvements which may

deviate from the specifications and descriptions stated herein, without obligation to
change previously manufactured products or to note the change.

NOTE: A neutralizing filter is the first unit installed in a water system after the outdoor raw water lines (*) when pH correction is
required.

Summary of Contents for NACF75

Page 1: ...Carbon Filter MMF Multimedia Filter NF Neutralizing Filter Page 5 of this manual contains important maintenance procedures required for the continued proper operation of this unit These MUST be perfor...

Page 2: ...ckwash Inches W x D x H Size Inches Weight Lbs NNF75 75 2 3 5 3 5 10 x 10 x 57 8 x 47 75 NNF10 1 0 3 5 4 11 x 11 x 58 9 x 48 115 NNF15 1 5 5 8 5 12 x 12 x 64 10 x 54 165 NNF20 2 0 6 10 7 14 x 14 x 62...

Page 3: ...nstallation kit or bypass to the control valve Make inlet and outlet water connections to meet applicable plumbing codes A 3 4 inlet line is recommended When sweat fittings are used solder the adapter...

Page 4: ...being used regeneration should be staggered by 15 minute intervals from 1 a m Manual Bypass Figure 3A In case of an emergency you can isolate your water filter from the water supply using the bypass...

Page 5: ...s tab out Moving clockwise round the skipper wheel adjust the remaining tabs using the following table as a guide Manual Regeneration Turn the manual regeneration knob clockwise This slight movement o...

Page 6: ...rge drum or pail The tank must be rinsed out completely and have no media or gravel left in it at all Loading the Media Pak Place the distributor tube Item B back down the center of the tank The top o...

Page 7: ...sure permanent electrical service check fuse interrupted plug or switch Timer is defective Replace timer Power failure Reset time of day Broken cogs on the 24 hour gear Replace 24 hour gear Timer moto...

Page 8: ...od shall be from the date thereof Lifetime Guarantee on Mineral Tanks and Brine Tanks Novatek will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of...

Reviews: