Novatek-electro RN-16TM Service Manual Download Page 4

- 4 - 

RN-16TМ 

                                                                                               

NOVATEK-ELECTRO

 

Voltage measurement accuracy, V (doesn’t exceed) 

Voltage hysteresis (returning ratio), V 

+ 5 

Illumination level hysteresis (returning ratio), % 

12 

Adjustable reaction time delay to Max/Min voltage interruptions, sec   

 0– 9,9     

Autoreclosing time delay (the RN-16TM will automatically close the 
contacts (turn ON the power load) as soon as the tripping parameters 
return to normal values), sec 

 0– 9,9   

Fixed reaction time to changes in illumination level, sec  

12 

Accuracy of the time clocks, seconds per day (not exceed)  

Accuracy to adjust schedule time setting, min (not exceed)  

Maximal number of events per day, 
Include      :    - switching ON………………………………………………….. 

        - switching OFF.………………………………………………… 

Events per week………………………………………………………………… 

60 
30 
30 
60

х7=420

 

Endurance  to the voltage absence (retention of  settings when supply 
voltage is absent, no less than) 

 
1 month 

Protection degree:       -  relay 

    - terminal 

ІР40

 

ІР20

 

Commutation life for the output contacts: 
-- under load 

16А, 

no less than, operations 

-- under load 5A, no less than, operations 

 
100 000 
1 000 000 

Power consumption (under load), VA,  not more than  

3,0 

Weight, not more than, kg 

0,150 

Dimensions, mm 

50

х

88

х

65 

Operating temperature, 

°

С

 

from -10 to  +55 

Storage temperature, 

°

С

 

from -20 to  +70 

 

3 GENERAL DESCRIPTION 

 

The mains power supply 240V 50Hz should be connected to 

«(1-1) – (2-2)»

 terminals of 

the 

RN-16TM

. For wiring convenience terminals 

1-1 

are the one connection point and 

2-2

 

terminals - another connection point. Output contacts have changeover relay 

3 – 4

In a time of exploitation of relay a strap is set 5-6.This strap is connect the internal 

accumulator of reserve clock motion. For warehousing of device it is recommended to take 
off this strap that will substantially increase lifetime of accumulator.  

Power load is being connected using terminals 

3-4

 

Output contacts characteristics (terminals 3-4-4-5) 

 

 

Max. current 

under U~250V 

A.C. 

Max. power when 

contacts are 

closed 

Max. 

switch. 

power 

Max. long-term 

safe voltage 

A.C./D.C. 

Max. current 

under U=30V 

D.C. 

Cos

φ

=0.4 

5A 

5000VA 

4000VA 

380/150 V 

5A 

Cos

φ

=1.0 

16A 

 

Summary of Contents for RN-16TM

Page 1: ...NOVATEK ELECTRO LTD Research and Manufacture Company RN 16TM LIGHT SENSITIVE MULTIFUNCTIONAL DAILY WEEKLY TIMER SERVICE MANUAL www novatek electro in...

Page 2: ...t hours blinking point minutes 16 hours 45 minutes II Mode U present voltage level correct to the nearest tenth 221 5 Volts III Mode F letter F space illumination level illumination level 35 IV Mode H...

Page 3: ...nu parameter input save the parameter and menu exit scrolling buttons 5 8 wiring terminals 6 seven segment indicator display 7 green LEDs to indicate the operation mode of the relay 9 strap of interna...

Page 4: ...er load 16 no less than operations under load 5A no less than operations 100 000 1 000 000 Power consumption under load VA not more than 3 0 Weight not more than kg 0 150 Dimensions mm 50 88 65 Operat...

Page 5: ...the operation mode F U H of the RN 16TM to set the operation mode and curtain user required set of parameters there are 2 independent sets of parameters programs that the user may keep in the device...

Page 6: ...rking capacity of an inner clock when disappearance of voltage it is necessary to establish a strap 5 6 Figure 1 Preliminary start up procedures include the following steps setting of the current time...

Page 7: ...ut contacts of RN 16TM ATTENTION In order to prevent possible electric shock all the connections of the power load should be performed according safety regulations and on the de energized RN 16TM To p...

Page 8: ...ss and while keeping button pressed set the required lower voltage threshold then release the button when the setting is done blinking dot Set lower voltage threshold value in the range 150 210 blinki...

Page 9: ...e in the device memory Save and Exit 14 Select dL 90 item blinking dot turn OFF time delay in case undervoltage detected 15 Press and while keeping button pressed set the required value then release t...

Page 10: ...orresponds to current hour 6 Press and set the current hours blinking hours position Set the value from 0 to 9 to that corresponds to current hour 1 5 _ _ 7 Press and set current minutes 1 5 _ _ blink...

Page 11: ...ind F PA mode 3 Press and while keeping button pressed set the required value then release the button when the setting is done blinking dot Set the value in the range 0 175 blinking dot 4 Press calibr...

Page 12: ...ress and Exit the menu 8 TO DELETE CURRENT SET OF ADJUSTMENTS 1 Perform steps 1 2 of the section 7 2 Press and while keeping button pressed delete the settings then release the button blinking dot Pre...

Page 13: ...KW THE RELAY MAY OPERATE WITH THE LOAD DIRECTLY VARIANT B IF THE POWER LOAD IS MORE THEN 16A 3 5 KW THE RELAY MUST OPERATE WITH THE POWER LOAD USING THE ADDITIONAL MAGNETIC CONTACTOR THAT WILL COMMUT...

Page 14: ...ackage and the RN 16TM material The Buyer must provide the protection of the timer against mechanical damages in transit 7 WARRANTY AND CLAIMS CONDITIONS Novatek Electro Ltd company warrants a trouble...

Reviews: