Novatek-electro PEF-320 Operating Manual Download Page 2

~ 2 ~ 

 

PEF-320 

                                  

                                                                          

NOVATEK-ELECTRO

 

ATTENTION! 

ALL REQUIREMENTS OF THIS OPERATING MANUAL ARE COMPULSORY TO BE MET!  

 

WARNING! 

–  P

RODUCT  TERMINALS  AND  INTERNAL  COMPONENTS  ARE  UNDER 

POTENTIALLY LETHAL VOLTAGE 
TO  ENSURE  THE  PRODUCT  SAFE  OPERATION

  IT  IS  STRICTLY  FORBIDDEN  THE 

FOLLOWING: 

  TO  CARRY  OUT  MOUNTING  WORKS  AND  MAINTENANCE

  WITHOUT  DISCONNECTING  THE 

PRODUCT FROM THE MAINS; 

  TO OPEN AND REPAIR THE PRODUCT INDEPENDENTLY; 

  TO OPERATE THE PRODUCT WITH MECHANICAL DAMAGES OF THE CASE. 

 

IT  IS  NOT  ALLOWED  WATER  PENETRATION  ON  TERMINALS  AND  INTERNAL  ELEMENTS  OF  THE 

PRODUCT. 

 

During operation and maintenance the regulatory document requirements must be met, namely: 

 

Regulations for Operation of Consumer Electrical Installations;  

 

Safety Rules for Operation of Consumer Electrical Installations;  

 

Occupational Safety when in Operation of Electrical Installations.  

 

Installation,  adjustment and maintenance of the product must be performed by qualified personnel having 

studied this Operating Manual. 

 

In  compliance  with  the  requirements  of  this  Operating  Manual  and  regulations  the  product  is  safe  for 

use. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PEF-320

Page 1: ...he development and production complies with requirements ISO 9001 2015 Dear customer Company NOVATEK ELECTRO LTD thanks you for purchasing our products You will be able to use properly the product aft...

Page 2: ...CHANICAL DAMAGES OF THE CASE IT IS NOT ALLOWED WATER PENETRATION ON TERMINALS AND INTERNAL ELEMENTS OF THE PRODUCT During operation and maintenance the regulatory document requirements must be met nam...

Page 3: ...and protect them against unallowable voltage variations in the mains According to the voltage presence and voltage quality on the phases the PEF 320 will automatically select the optimum phase in lim...

Page 4: ...ional relay output contacts A 5 Device operating capability phase voltage V 400 Short time allowable operating capability maximal phase voltage V 450 Power consumption under load W not more than 1 2 P...

Page 5: ...ters at one of the phases within acceptable limits the PEF 320 will switch the load to this phase during the time of AR 4 THE INTENDED USE 4 1 Preparation for operation 4 1 1 Preparation for connectio...

Page 6: ...time of return to the priority phase After the setting the threshold values the device is ready for operation with the load It is allowed to change the thresholds values Umax Umin Tr and Ton during th...

Page 7: ...helf life is 3 years 6 3 Warranty period of the device operation is 5 years from the date of sale During the warranty period of operation in the case of failure of the device the manufacturer is respo...

Page 8: ...______________________________________________ _______________________________________________________________________________ The Company is grateful to you for the information about the quality of t...

Reviews: