background image

 

© NOVATEC, Inc, 2018 All Rights Reserved         23               Document: SVP IM 7 FEB 2018

 

15 WARRANTY – NOVATEC, INC. - Effective Date  7 FEB 2018

NOVATEC, INC. offers COMPREHENSIVE PRODUCT WARRANTIES on all 
of our plastics auxiliary equipment. We warrant each NOVATEC manufactured 
product to be free from defects in materials and workmanship, under normal 
use and service for the periods listed under 

“Warranty Periods”. 

The 

obligation of Novatec, under this warranty, is limited to repairing or 
furnishing, without charge, a similar part to replace any part which 
fails under normal use due to a material or workmanship defect, within 
its respective warranty period. It is the purchaser’s responsibility to 
provide Novatec with immediate written notice of any such suspected 
defect.  W arranted replacem ent parts are billed and shipped freight 
pre-paid. The purchaser must return the suspect defective part, freight 
prepaid and with identifying documentation to receive full credit for the 
part returned. Novatec shall not be held liable for damages or delay 
caused by defects. No allowance will be made for repairs or alterations 
without the written consent or approval of Novatec.  

The provisions in equipment specifications are descriptive, unless 
expressly stated as warranties. The liability of Novatec to the 
purchaser, except as to title, arising out of the supplying of the said 
equipment, or its use, whether based upon warranty, contract or 
negligence, shall not in any case exceed the cost of correcting defects 
in the equipment as herein provided. All such liability shall terminate 
upon the expiration of said warranty periods. Novatec shall not in 
any event be held liable for any special, indirect or consequential 
damages. Commodities not manufactured by Novatec are warranted 
and guaranteed to Novatec by the original manufacturer  and then only 
to the extent that Novatec is able to enforce such warranty or 
guaranty. Novatec, Inc. has not authorized anyone to make any 
warranty or representation other than the warranty contained here. 
Non-payment of invoice beyond 90 days will invalidate the warranty. A 
renewed 

warranty can be purchased directly from Novatec.

 
Please note that we always strive to satisfy our customers in whatever manner is deemed most expedient to overcome any issues in 
connection with our equipment. 

 
Warranty Periods:  

Note: All warranty periods commence with the shipment of the equipment to the customer. 
 

5-Year (Except 1-Year on Non-Novatec Buy-Out Items)

 

Resin Drying to Include 

 
NovaWheel™ Dryers * 
Dual Bed Dryers 
NovaDrier *  
NDM-5 Membrane Dryer 
Gas-Fired Process Heaters  
Gas-Fired Regeneration Heaters  
Drying Hoppers 
Central Drying Hopper Assemblies 
Heater/Blower Units and Hot-Air Dryer              
Silo Dehumidifiers 
NovaVac Dryers * 
Nitrogen NovaDriers (Nitro) 
DryTemp Plus 

 
Resin Blending and Feeding to Include 

 
WSB Blenders, MaxiBatch & Feeders * 
Gaylord Sweeper Systems 
 
 

Downstream Extrusion Equipment to Include 

 
C and NC Bessemer Series Cutters  
NPS Bessemer Series Pullers 
NPC Mini Puller/Cutter 
All NS Series Servo Saws 
All Cooling and Vacuum Tanks Manufactured by Novatec

Central System Controls to Include 

 
FlexTouch™ Series Controls 
FlexXpand™ Series Controls 
OptiFlex™ Series Controls 
PLC Communications Modules 
Greenboard Communications Modules 
LOGO! Mini PLC 
MCS-600 Series Controls – (Distributed I/O) 
MCS-400 Series Controls 
CL Silo Manager 

 

 

Moisture Measurement Equipment to Include 

MoistureMaster® 
 

PET Resin Crystallizers 

 
 
 

 

Resin Conveying and Systems Components to Include 

GSL Series Vacuum Loaders  
GlassVu Loaders, Receivers and Hoppers 
VL/VLP Series Loaders 

 

VRH, VR, VR-FL & VRP Series Receivers 

 

Compressed Air Loaders 
AL-B Barrel Loader 

 

Cyclone Dust Collectors 

 

Conveying System Accessories 
Surge Bins 
Valves and Accessories 
Electronic Metal Separators 
Quick Select Manifolds 
Tilt Tables 
Filter Dust Collectors 
Drawer Magnets 
Velocity Control Valves

     3-Year

Resin Conveying System Components to Include 

 
** VPDB Vacuum Positive Displacement Pumps   
** SVP Vacuum Pumps 
** MVP Vacuum Pumps            
** Railcar Unloading Systems 
   

 

 
 

 
 

                                                              

 

 

**5-Year Extended Warranty

 - When a MachineSense® data plan is activated for products with **, Novatec automatically extends the warranty to 5 

years.  The data plan must be activated within 60 days after product shipment, and remain active through the warranty period to maintain extended warranty 
eligibility.  The first 6-months of data plan usage is free from Novatec. 
 

     1-Year

Infrared Dryers    
UltraVac Vacuum Pumps 

Vacuum Regenerative Blower Pumps                                                                                    
Custom Equipment of any kind unless otherwise specified 

 

 
 
 

Summary of Contents for SVP-10

Page 1: ...Instruction Manual SVP IM 7 FEB 2018 NOVATEC Inc 2018 All Rights Reserved Models SVP 3 SVP 5 SVP 10 Silencer Positive Displacement Vacuum Pump...

Page 2: ...espond to any of your requests DISCLAIMER NOVATEC Inc shall not be liable for errors contained in this Instruction Manual nor for misinterpretation of information contained herein NOVATEC shall not in...

Page 3: ...n Valve DSV 8 7 5 Closed Loop Vacuum System 9 7 6 Ambient Air Vacuum System 9 8 ELECTRICAL INSTALLATION 10 9 STANDARD SPECIFICATIONS 3000 ft Elevation and below 16 10 OPERATING AT HIGH ELEVATIONS 3000...

Page 4: ...er elevations and as a result the compression of air by the pump requires more work for vacuum conveying In these higher altitude applications the pressure relief valve of SVP pumps must be adjusted o...

Page 5: ...e on delivery receipt and report immediately to trucking company 5 GENERAL INSPECTION When the unit is unpacked make a visual inspection looking for missing parts or damage that may have occurred duri...

Page 6: ...NOVATEC Inc 2018 All Rights Reserved 6 Document SVP IM 7 FEB 2018 6 SPECIFICATIONS...

Page 7: ...ice or in the case of an emergency Compressed Air Supply Clean compressed air should be supplied to the SVP pump s vacuum breaker valve regulator providing 80 to 120 psi A filter not supplied should b...

Page 8: ...room Requires a separate Relief Vent in a closed system Includes 3 Bolt Coupler and pump adapter fitting For use with either VRB or SVP pumps 7 4 Closed Loop Relief Vent CLR Provides Pressure Relief i...

Page 9: ...Loop Vacuum System 7 6 Ambient Air Vacuum System Machine Mounted Vacuum Receivers Material Selection Device Ambient Air Passes Through Vacuum Purge Valve Conveys Material Ambient Air Conveying Illustr...

Page 10: ...ext page See FLA specification table on page 16 Connect control wiring from the conveying system control panel to the same electrical enclosure as shown on the wiring schematic for the conveying syste...

Page 11: ...NOVATEC Inc 2018 All Rights Reserved 11 Document SVP IM 7 FEB 2018 SVP Pump Wiring 24 vdc control voltage Typical for 460 3 60 and 400 3 50...

Page 12: ...NOVATEC Inc 2018 All Rights Reserved 12 Document SVP IM 7 FEB 2018 SVP Pump Wiring 115 vac control voltage Typical for 460 3 60 and 400 3 50...

Page 13: ...NOVATEC Inc 2018 All Rights Reserved 13 Document SVP IM 7 FEB 2018 SVP Pump Wiring 24 vdc control voltage Typical for 575 3 60...

Page 14: ...NOVATEC Inc 2018 All Rights Reserved 14 Document SVP IM 7 FEB 2018 SVP Pump Wiring 115 vdc control voltage Typical for 575 3 60...

Page 15: ...nd voltage Horse Power Voltage FLA KVA SVP 3 3HP 208 3 60 9 4 3 5 230 3 60 8 5 3 5 400 3 50 5 2 3 5 460 3 60 4 3 3 5 575 3 60 3 5 3 5 SVP 5 5HP 208 3 60 14 3 5 0 230 3 60 13 0 5 0 400 3 50 7 3 5 0 460...

Page 16: ...eric pressure is lower at higher elevations and as a result the compression of air by the pump requires more work for vacuum conveying In these higher altitude applications the pressure relief valve o...

Page 17: ...1 Motor Starter 208V 00834 01944 01945 230V 00834 01944 01947 460V 00838 00834 00944 575V 00843 00838 00942 1 Filter Element hf 047 hf 047 hf 047 1 Regulator 50154 1 Regulator Bracket 07 1397 Lubrica...

Page 18: ...the first week the first month and the first 3 months These inspections will be indicative of how often future maintenance will be necessary 12 1 EVERY WEEK Inspect the Filter cartridge Clean or repla...

Page 19: ...hown on the next page and carefully examine each belt for excessive stretch looseness frayed surfaces or exposed cord Replace all belts if one or more belts are found to be excessively worn Always rep...

Page 20: ...l Them carefully onto each sheave pulley All belts must be replaced as a set 4 Re tension the belts with the sliding motor base according to the chart below Note new belts require greater initial tens...

Page 21: ...T OVERFILL OIL SUMPS or damage to the blower may occur 4 The oil level may naturally rise and or fall in the gauge during operation but the oil level should not fall below the middle of the site gauge...

Page 22: ...ave There should be1 4 3 8 between the blower face and the sheave CAUTION FILL ONLY TO CENTER OF SIGHTGLASSES DO NOT OVERFILL Damage to Pump and voiding of warranty will result LUBRICATION REQUIREMENT...

Page 23: ...note that we always strive to satisfy our customers in whatever manner is deemed most expedient to overcome any issues in connection with our equipment Warranty Periods Note All warranty periods comme...

Page 24: ...ne has been exposed to ozone 2 NovaVac Dryer The ability of the canisters to hold vacuum will be compromised if the vacuum seal edge is damaged from mishandling We do not warranty canisters damaged fr...

Reviews: