Full Load Amperage and KVA ratings for SVP vacuum pumps by model and voltage.
Horse Power
Voltage
FLA
KVA
SVP-3
3HP
208/3/60
9.4
3.5
230/3/60
8.5
3.5
400/3/50
5.2
3.5
460/3/60
4.3
3.5
575/3/60
3.5
3.5
SVP-5
5HP
208/3/60
14.3
5.0
230/3/60
13.0
5.0
400/3/50
7.3
5.0
460/3/60
6.5
5.0
575/3/60
5.0
5.0
SVP-10
10 HP
208/3/60
29.5
7.8
230/3/60
26.8
7.8
400/3/50
15.6
7.8
460/3/30
13.4
7.8
575/3/60
10.7
7.8