8 UPDATING FIRMWARE 

 
When the NovaDrier is powered on, the Temperature Control Dual Display will show the current 
firmware version across both displays. When required or advised, firmware updates are loaded into 
the NovaDrier via a SD flash memory card.   
 
The SD flash memory card slot is located within the NovaDrier’s electrical cabinet. Firmware updates 
can be supplied via shipment of a pre-loaded SD flash memory flash card or may be downloaded or 
sent via email and loaded onto your own SD flash memory card. 
 
Firmware Updates apply when the NovaDrier is turned on.  After the firmware is updated, the 
firmware file is deleted from the SD card.  This is to prevent repeated update attempts of the firmware 
in the event that the flash card is left in the SD slot indefinitely.  If more than one NovaDrier is to be 
updated, request additional pre-loaded SD cards from NOVATEC, or instructions on copying the file 
onto your computer prior to updating, so the card can be reloaded for updating other dryers.   
 

Procedure:

 

1.  Disconnect power to the NovaDrier prior to opening the electrical cabinet.  The cabinet door 

opens by rotating the two ¼-turn latches counter-clockwise. Locate the elevated printed 
circuit board in the lower left corner of the cabinet and the SD card slot on its base. 

2.  Insert the SD update card into the slot until it clicks.  Note that some dryers have “large” 

slots (about an inch wide) and some have “small” slots (about ½” wide).  
Small slots take the SD card directly.  Large slots require the use of an 
SD card adaptor. 

3.  Close the electrical box door and close the ¼ - turn latches.  Reconnect 

power. 

4.  To update the firmware, turn on the machine.  On power up, the UPPER 

and LOWER displays will show “UPT” and an incremental counter from 
000 to 100.  It will then display the new firmware version. 

5.  Once the updated version disappears and temperature is once again displayed on the 

readouts, the update is complete.  Shut the dryer off once again and disconnect power.  
Open the cabinet and remove the SD card. 

6.  Default settings must be reloaded following a firmware update. At the dryer’s dual control 

readouts, use the upper “UPPER” display and press the upper left and lower right buttons 
simultaneously to enter Set-up mode. 

7.  Use the up and down buttons of the UPPER readout to navigate to the setting “LdF” (Load 

Factory defaults), then hold the Select (upper left) button down for 2 seconds. 

8.  When the Select button is released “dne” (done) will be displayed on the top readout, 

indicating the factory default settings are done being restored. 

9.  NovaDrier’s equipped with the Energy Saver feature must be have this feature re-activated 

and the Energy Saver temperature set, to complete the firmware update process. 

10. At the dryers’ dual control readouts, use the upper “UPPER” display and press the upper 

left and lower right buttons simultaneously to once again, enter Set-up mode. 

11. Use the up and down buttons to navigate to the setting “ES” (Energy Saver). 
12. Press the Select (upper left) button and view ”Off” setting on the readout.  The desired 

energy saver temperature may now be set with the up and down arrows. 

13. Lock in your setting by pressing the lower left Enter button and the dryer is now ready to 

operate normally with the updated firmware. 

Summary of Contents for NovaDrier ND-100

Page 1: ...4 701 B1 Document ND IM 3 JAN 2017 NovaDrier MEMBRANE DRYER for Plastics MODELS ND 7 ND 25 ND 50 ND 75 ND 100 ND 150 ND 200 NOVATEC Inc 2017 All Rights Reserved NOTE See important information about ai...

Page 2: ...roperly respond to any of your requests Instruction Manual ND IM 3 JAN 2017 Model ___________________________ Serial ____________________________ DISCLAIMER NOVATEC Inc shall not be liable for errors...

Page 3: ...3 3 Condensate Drains 10 4 DESCRIPTION OF OPERATION 11 5 INITIAL START UP OPERATION 12 5 1 Turning The Dryer On 12 5 4 Other Parameters 14 6 USING THE 7 DAY TIMER OPTION 15 7 SETTING ENERGY SAVER OPTI...

Page 4: ...rovide you with proper procedures to insure that you will be completely satisfied with your purchase Please review this manual carefully 1 1 Unpacking Caution should be exercised to make sure the equi...

Page 5: ...ause them to loosen Inside of the hopper door the 2 perforated air diffuser tubes upper lower should be thoroughly cleaned to remove any dust moisture or oil that may have accumulated during shipment...

Page 6: ...e sections of the hopper together are tight particularly the one at the lower part of the hopper that connects the bottom of the conical section Note that the clamp ring that attaches the hopper lid d...

Page 7: ...ox UPPER air pressure regulator setting R2 located inside the lower part of the control box See sticker inside control box Low air pressure switch 70 PSIG 4 7 BagG Over temperature shut down set point...

Page 8: ...TE THIS EQUIPMENT 3 2 Connecting Power Refer to the specifications in Section 2 and the mechanical and electrical drawings provided Connect the required electrical power to the unit through a main lin...

Page 9: ...ements IMPORTANT NOTE The introduction of OZONE to the flow of compressed air will damage the membrane and void the warranty OZONE in the atmosphere near the air compressor intake can also damage the...

Page 10: ...ot designed to remove liquid water Make sure that hazardous vapors like solvents or ozone are not being introduced into the compressed air system that is feeding the NovaDrier 3 3 3 Condensate Drains...

Page 11: ...e hopper is controlled by a thermocouple and a solid state temperature controller located in the right side of the control box and it is the top controller labeled UPPER HEAT The rest of the compresse...

Page 12: ...and the information in this Technical Manual Contact NOV ATEC if there are any questions about how to operate or maintain this equipment Before starting the compressed air inlet valve located on the...

Page 13: ...int 1 Find the board behind the dew point display 2 Press HOLD one of the two white buttons 3 The display will change to the new selection 4 Release the button and the dew point readout will be in the...

Page 14: ...point 2 While set point is displayed press to increase the set point or to reduce the set point 3 The control will revert back to display actual temperature and the dryer s heaters will respond displ...

Page 15: ...pears Press OK 7 Press to choose hour of day for ON Press OK 8 Press to choose minutes of ON hour Press OK 9 Use to choose Mon Sun Mon Sat Mon Friday Sat Sun or single day Press OK 10 Prog 02 appears...

Page 16: ...Heater will turn back on and if the air LOWER to the heater was OFF the air LOWER will then re open Note If the Energy Saver function cycles faster than every five minutes compressed air will never t...

Page 17: ...e slots require the use of an SD card adaptor 3 Close the electrical box door and close the turn latches Reconnect power 4 To update the firmware turn on the machine On power up the UPPER and LOWER di...

Page 18: ...al and ample air is supplied 85 psi as read on the pressure gauge on the side of the cabinet 2 Drain water and clean drainage tubes and or base of filters or replace both filters NOTE Visible liquid i...

Page 19: ...on primary No voltage on secondary See code A Check fuse if ok power to primary replace transformer C Light bulb Burnt out Replace D Heater amperage Voltage correct but amps incorrect check both heat...

Page 20: ...the set points on the label inside the box O LOWER orifice Orifice plugged with material This is a hex shaped brass fitting screwed into air inlet of LOWER heater H1 Remove the orifice clean out the p...

Page 21: ...he compressed air LOWER system must be prevented from entering the dryer as this will permanently damage the dryer media and it may have to be replaced Every Month A Check system for air leaks or flow...

Page 22: ...all ended wrench typically works best 5 32 will also work Remove 8 screws total 3 0 Remove the existing filter elements 4 0 Insert the new filter elements into each filter bowl and carefully refit int...

Page 23: ...ed on top the control cabinet To check or replace this filter the system must be shut down and the filter housing should be cool to the touch Carefully remove the filter housing The filter element can...

Page 24: ...C by the original manufacturer and then only to the extent that NOVATEC is able to enforce such warranty or guaranty NOVATEC Inc has not authorized anyone to make any warranty or representation other...

Reviews: