background image

NovaStar

NovaStar

NovaStar

NovaStar Tech

Tech

Tech

Tech Co.,

Co.,

Co.,

Co., Ltd

Ltd

Ltd

Ltd....

Phone

Phone

Phone

Phone

: NovaStar (Xian) +86 29 8450 7048 NovaStar (Shenzhen) +86 755 3359 2492

Website

Website

Website

Website

:

www.novastar-led.com

2

3.

3.

3.

3. Outline

Outline

Outline

Outline drawing

drawing

drawing

drawing

Figure-1

Figure-2

 

Summary of Contents for Nova M3 MFN300

Page 1: ... M3 function card MFN300 can manage power distribution box of LED display It has functions of ambient temperature and humidity detecting With integrated audio output it can also achieve audio transmission together with sending card It s light sensor supportive to achieve automatic brightness adjustment of LED display And with both Ethernet and RS232 interface available it s very convenient and rel...

Page 2: ... Co Co Co Ltd Ltd Ltd Ltd Phone Phone Phone Phone NovaStar Xian 86 29 8450 7048 NovaStar Shenzhen 86 755 3359 2492 Website Website Website Website www novastar led com 2 3 3 3 3 Outline Outline Outline Outline drawing drawing drawing drawing Figure 1 Figure 2 ...

Page 3: ...add remove and rename external device configuration monitor data updating and power supply management 4 1 4 1 4 1 4 1 Hardware Hardware Hardware Hardware connection connection connection connection 4 1 1 4 1 1 4 1 1 4 1 1 Serial Serial Serial Serial communication communication communication communication Connect function card to computer directly by RS232 serial cable Figure 3 4 1 2 4 1 2 4 1 2 4 ...

Page 4: ...vastar led com 4 Connect function card between any two receiving cards Figure 5 Connect function card to the last receiving card Figure 6 4 2 4 2 4 2 4 2 Software Software Software Software operation operation operation operation Run Nova Nova Nova NovaLCT LCT LCT LCT Mars Mars Mars Mars control software click Function Function Function Function Card Card Card Card button to open Function Card Man...

Page 5: ... unction unction unction card card card card Configuration Configuration Configuration Configuration Use the menu in Figure 6 to configure function card including add remove rename a function card modify serial port and replace serial port Add Add Add Add Serial Serial Serial Serial port port port port Add a function card which is connected to the serial port Ethernet Ethernet Ethernet Ethernet po...

Page 6: ...ort Port Port Set the selected serial port as one that no function card has been configured for it Replace Replace Replace Replace Serial Serial Serial Serial Port Port Port Port replace the selected serial port with the one which is configured but the configured device type is different from that actually connected or is actually not connected Note The icon is only available when the following re...

Page 7: ...ad Read Read the time of selected function card and show it on the page Set Set Set Set Set current computer time of to the selected function card Set Set Set Set notes notes notes notes Set note for each power supply of selected function card Start Start Start Start delay delay delay delay Set the delay time for starting power of function card After successful setting the start of each power supp...

Page 8: ...op Turn off all the power supplies controlled by selected function card In auto control mode the schedule will be disabled when the emergency stop operation is executed unless Start Start Start Start All All All All button is clicked again Manual Manual Manual Manual Set the power control into manual control mode Use Start button or Stop button to control each corresponding power manually Auto Aut...

Page 9: ...r Shenzhen 86 755 3359 2492 Website Website Website Website www novastar led com 9 Select Manual to achieve up to 8 way power supplies control manually Figure 9 4 2 2 2 4 2 2 2 4 2 2 2 4 2 2 2 Auto Auto Auto Auto control control control control Select Auto to achieve up to 8 way power supplies control automatically according to software settings ...

Page 10: ...rol mode the schedule will be disabled when the emergency stop operation is executed unless Start Start Start Start All All All All button is clicked again 2 Auto power control is conducted according to the time on function card Check function card time before setting schedule before setting auto control time To check the function card time click Read Read Read Read button in the Function Card Tim...

Page 11: ... 2 3 Software Software Software Software Control Control Control Control The page for software power control is shown in Figure 10 Figure 11 Copy Copy Copy Copy Copy current power control schedule so that it can be pasted to other function cards Paste Paste Paste Paste Paste the copied power control schedule to the current function card View View View View log log log log Check the log of the cont...

Page 12: ...te www novastar led com 12 Figure 12 Select Select Select Select the the the the Log Log Log Log File File File File Select the log to be checked Select the log to be checked find the function card to be checked in the left list the detailed information will be shown on the right Edit Edit Edit Edit Click this button to open the page for editing the power supply control schedule as shown in Figure...

Page 13: ...Delete Delete Delete the selected items Clear Clear Clear Clear Clear all existing custom control lists Power Power Power Power switch switch switch switch Check power switches to be controlled Date Date Date Date Check the day of the week to be controlled Time Time Time Time Set the time to be controlled Add Add Add Add Add the edited power control information to the left list Note 1 Do not stop ...

Page 14: ...ll command the hardware to conduct corresponding actions only when the clock time reaches the time set by the software 4 2 3 4 2 3 4 2 3 4 2 3 Monitor Monitor Monitor Monitor data data data data Click Monitor Monitor Monitor Monitor Data Data Data Data button in the Function Card Management page to open the page for data monitoring as shown in Figure 13 Figure 14 Refresh Refresh Refresh Refresh Ob...

Page 15: ...Device Device Device button in the Function Card Management page to open the page for external devices management as shown in Figure 14 Figure 15 Refresh Refresh Refresh Refresh Refresh the brightness value read by the configured external light sensor Save Save Save Save Save external device type settings to file Save Save Save Save button must be clicked if any modification made to the external d...

Page 16: ...NovaStar NovaStar Tech Tech Tech Tech Co Co Co Co Ltd Ltd Ltd Ltd Phone Phone Phone Phone NovaStar Xian 86 29 8450 7048 NovaStar Shenzhen 86 755 3359 2492 Website Website Website Website www novastar led com 16 Figure 16 ...

Reviews: