background image

 

 

 

 

 

 

 

 

 

 

 

 

 

             

     

JE-238

 

 

 

User’s Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for JADAK JE-238

Page 1: ...JE 238 User s Manual...

Page 2: ...Connecting the JE 238 with USB Port 11 Connecting the JE 238 with Serial Port 12 Interface Options 13 USB HID Keyboard Emulation 13 USB COM Port Emulation 13 Keyboard Country Layout 14 Keyboard Contr...

Page 3: ...20 Beeper Time Good Read 20 No Reads 21 No Read Message 21 Miscellaneous Indicators 22 Beeper Beep on BEL 22 Beeper Power Up Beep 22 Aimer Mode 23 Aimer Delay 23 Trigger Commands 24 Trigger Modes 24 M...

Page 4: ...vision 29 Show Revision Time 29 Chapter 5 Data Editing Data Editing Overview 30 Transmit AIM ID Character 30 Prefixes 31 Prefix Block String 31 Prefix Clear 31 Suffixes 32 Suffix Block String 32 Suffi...

Page 5: ...8 Code 11 Defaults 38 Code 11 On Off 38 Code 11 Minimum and Maximum Length 38 Code 11 Check Digit 39 Code 128 40 Code 128 Defaults 40 Code 128 On Off 40 Code 128 Minimum and Maximum Length 40 ISBT 128...

Page 6: ...8 On Off 45 EAN 13 JAN 13 45 EAN 13 JAN 13 Defaults 45 EAN 13 JAN 13 On Off 45 GS1 128 Formerly UCC EAN128 46 GS1 DataBar Formerly RSS 14 47 GS 1 DataBar Defaults 47 GS 1 DataBar On Off 47 GS1 DataBa...

Page 7: ...k Digit 50 Matrix 2 of 5 51 Matrix 2 of 5 Defaults 51 Matrix 2 of 5 On Off 51 Matrix 2 of 5 Minimum and Maximum Length 51 MSI 52 MSI Defaults 52 MSI On Off 52 MSI Minimum and Maximum Length 52 MSI Che...

Page 8: ...d Maximum Length 57 2D Matrix Symbologies 58 Aztec Code 58 Aztec Code Defaults 58 Aztec Code On Off 58 Aztec Code Minimum and Maximum Length 58 Data Matrix 59 Data Matrix Defaults 59 Data Matrix On Of...

Page 9: ...stomer Support Obtaining Technical Assistance or Factory Service 63 Limited Warranty 64 Appendices Appendix A1 1 Command Format 65 Appendix A1 2 Command List and Standard Default Parameters 68 Appendi...

Page 10: ...ers are factory programmed for the most common terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide or by sendi...

Page 11: ...mbologies with smaller bars or elements lower mil size should be read closer to the unit Symbologies with larger bars or elements higher mil size should be read farther from the unit To read multiple...

Page 12: ...computer The driver is available from your JADAK technical support contact Note No driver is required when using the USB HID Keyboard interface 2 Turn off power to the terminal computer 3 Connect the...

Page 13: ...32 cable to the JE 238 and connect the D Sub connector to the terminal computer 3 Connect Power to the JE 238 cable 4 Once the JE 238 has been fully connected power up the computer Note When connectin...

Page 14: ...JE 238 will not be able to receive serial commands from the host A JE 238 paired with an interface board with a push button trigger or hardware trigger line will be necessary to allow the JE 238 to s...

Page 15: ...n use the following KBD_CTY commands or programming barcodes to set the specific Keyboard layout for your language Default United States Note These commands are not applicable for RS 232 versions Unit...

Page 16: ...age Return hex 0D it will send CR as readable ASCII text Default Disabled Note These commands are not applicable for RS 232 versions of the JE 238 Enable Disable Numeric Keypad Mode Use these commands...

Page 17: ...Baud Rate the data from the scanner will be sent to the terminal at the specified rate The baud rate for RS 232 interface can be set by sending the serial command 232BAUD x where x is one of the allo...

Page 18: ...computer Note The JE 238 must be power cycled after programming this interface No Parity 7 Data bits 1 Stop bits No Parity 7 Data bits 2 Stop bits No Parity 8 Data bits 1 Stop bits Even Parity 7 Data...

Page 19: ...18 Default Options Default Settings Scan the following code revert the unit to its custom default settings Note The JE 238 must be power cycled after programming this command Note Please contact JADAK...

Page 20: ...Off in response to a good read Turning this option off only turns off the beeper s response to a good read indication All error and menu beeps are still audible Note the JE 238 requires an interface...

Page 21: ...the JE 238 requires an interface board or host equipped with a beeper for this function Default Medium Low Medium High Beeper Time Good Read Scan one of the following codes to set the duration of the...

Page 22: ...enable or disable the No Reads message Default Disable No Read Enable No Read Disable No Read No Read Message The aforementioned No Read signer NR can be changed if you require a custom message By us...

Page 23: ...t to the scanner Note the JE 238 requires an interface board or host equipped with a beeper for this function Default Disabled Enable Disable Beeper Power Up Beep Scan one of the following codes to en...

Page 24: ...anner s illumination will not show until the delay time has passed This command sets the Aimer Delay Time in steps of one millisecond from 1ms up to 4000ms 4 seconds Default Off Several commonly used...

Page 25: ...t page TRGON This command turns the trigger ON TRGOFF This command turns the trigger OFF Trigger Modes Manual Trigger level When in manual trigger mode the JE 238 imager scans until a bar code is read...

Page 26: ...ively to set a custom Trigger Time Note TRGTIME 0 sets an infinite Trigger Time Out Sample settings Infinite Trigger Time Out Trigger Time Out 1 0 seconds Trigger Time Out 5 0 seconds Trigger Time Out...

Page 27: ...No Good Read delay Good Read delay 0 2 seconds Good Read delay 0 5 seconds Good Read delay 1 0 seconds Good Read delay 2 0 seconds Good Read delay 5 0 seconds If a different delay time other than thos...

Page 28: ...milliseconds Note Re read Delay only works when the JE 238 is in Presentation Mode Setting examples No Re read delay Re read delay 0 1 seconds Re read delay 0 6 seconds Re read delay 1 0 seconds Re r...

Page 29: ...y sending the serial command EXP_MAX x where x is a value between 1 and 7874 or by building a menu command barcode Please contact JADAK if assistance is needed Default value 100 Setting examples Targe...

Page 30: ...cts of the JE 238 fixed mount scanner Report the list of available Programming Commands All of the supported serial commands of the JE 238 along with a short description and the current and default se...

Page 31: ...essage string The selections in this section are used to build the user defined data into the message string The following illustration shows the breakdown of a message string Transmit AIM ID Characte...

Page 32: ...of characters as the Prefix or by scanning the barcode below and then set the ASCII character by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is need...

Page 33: ...one or more sets of two hexadecimal digits to define a specific ASCII character or set of characters as Suffix or by scanning the barcode below and then set the ASCII character by scanning the digit...

Page 34: ...ep on when snapping an image 0 Off T 1 wait for trigger 0 Off More details and additional arguments for IMGSNAP can be found in the HELP dump Send an Image to Host Use the command IMGGETX to get or se...

Page 35: ...t 0 Disabled Enable Decode Windowing Disable Decode Windowing To define the Decode Window one needs to set the boundaries for Top Bottom Left and Right These boundaries are defined by pixel values wit...

Page 36: ...e boundary pixel value by scanning the digit codes and the SAVE barcode in Appendix B Please contact JADAK if assistance is needed Default Left boundary WINDECL 256 Default Right boundary WINDECR 384...

Page 37: ...R Code EAN JAN 8 UPC A GS1 128 UPC E GS 1 Databar RSS 14 UPC E1 All Symbologies If you want to be able to decode all the symbologies allowable for your JE 238 scan the All Symbologies On code Enable A...

Page 38: ...ation with numerical values to set the minimum and maximum length for allowed Codabar barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbology can...

Page 39: ...with numerical values to set the minimum and maximum length for allowed Code 11 barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbology can be se...

Page 40: ...r a check digit to decide if the code is valid Code 11 usually has one check digit and some barcodes have two check digits Either option can be chosen to be just validated or validated and transmitted...

Page 41: ...minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 0 and 55 or by scanning one of the barcodes below and...

Page 42: ...mum length 48 The minimum and maximum length for this symbology can be set either by sending the serial command shown under the barcodes below with a value between 0 and 48 or by scanning one of the b...

Page 43: ...efault No Check Digits Disable Enable but don t transmit Enable and transmit Code 39 Convert to Code 32 Pharmacode Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry Scan the...

Page 44: ...h numerical values to set the minimum and maximum length for allowed Code 93 barcodes Default minimum length 0 Default maximum length 55 The minimum and maximum length for this symbology can be set ei...

Page 45: ...aximum Length Use the following commands in combination with numerical values to set the minimum and maximum length for allowed Composite Code barcodes Default minimum length 1 Default maximum length...

Page 46: ...his code EAN 8 JAN 8 On Off Scan one of the codes below to enable or disable EAN 8 Default Enabled Enable Disable EAN 13 JAN 13 EAN 13 JAN 13 Defaults Set the EAN 13 settings to their default configur...

Page 47: ...JADAK JE 238 User s Manual Page 46 GS1 128 Formerly UCC EAN128 Scan one of the codes below to enable or disable GS1 128 Decoding Default Enabled Enable Disable...

Page 48: ...On Off Scan one of the codes below to enable or disable GS1 DataBar Default Enabled Enable Disable GS1 DataBar Limited Formerly RSS Limited GS 1 DataBar Limited Defaults Set the GS 1 Databar settings...

Page 49: ...e following commands in combination with numerical values to set the minimum and maximum length for allowed GS 1 Databar Expanded RSS Expanded barcodes Default minimum length 4 Default maximum length...

Page 50: ...in combination with numerical values to set the minimum and maximum length for allowed Interleaved 2 of 5 barcodes Default minimum length 6 Default maximum length 30 The minimum and maximum length for...

Page 51: ...it The scanner may look for a check digit to decide if the code is valid Interleaved 2 of 5 s USS Uniform Symbology Specification Check digit can be validated and if desired transmitted too Default Di...

Page 52: ...ination with numerical values to set the minimum and maximum length for allowed Matrix 2 of 5 barcodes Default minimum length 4 Default maximum length 55 The minimum and maximum length for this symbol...

Page 53: ...merical values to set the minimum and maximum length for allowed MSI barcodes Default minimum length 4 Default maximum length 48 The minimum and maximum length for this symbology can be set either by...

Page 54: ...l If the MSI codes include two check digits scan the Two MSI Check Digits bar code to enable verification of the second check digit Default Enable One Check Digit but don t transmit Disable MSI Check...

Page 55: ...le UPC A Default Enabled Enable Disable UPC A Check Digit The check digit is the last character and is used to verify data integrity This digit is always checked but it may be chosen whether or not to...

Page 56: ...Digit The check digit is the last character and is used to verify data integrity This digit is always checked but it may be chosen whether or not to transmit it Default Transmit Check Digit Transmit U...

Page 57: ...numerical values to set the minimum and maximum length for allowed PDF417 barcodes Default minimum length 1 Default maximum length 2750 The minimum and maximum length for this symbology can be set ei...

Page 58: ...h numerical values to set the minimum and maximum length for allowed MicroPDF417 barcodes Default minimum length 1 Default maximum length 366 The minimum and maximum length for this symbology can be s...

Page 59: ...ion with numerical values to set the minimum and maximum length for allowed Aztec barcodes Default minimum length 1 Default maximum length 3832 The minimum and maximum length for this symbology can be...

Page 60: ...erical values to set the minimum and maximum length for allowed Data Matrix barcodes Default minimum length 1 Default maximum length 3116 The minimum and maximum length for this symbology can be set e...

Page 61: ...ical values to set the minimum and maximum length for allowed Maxi Code barcodes Default minimum length 1 Default maximum length 150 The minimum and maximum length for this symbology can be set either...

Page 62: ...values to set the minimum and maximum length for allowed QR Code barcodes Default minimum length 1 Default maximum length 7089 The minimum and maximum length for this symbology can be set either by s...

Page 63: ...n Contrast 35 minimum print contrast ratio Voltage Requirements TTL Serial 3 3V DC 5 USB 5 0V DC 5 Current Draw Typical Scanning Standby Idle 5V DC 220mA 2 5mA 60mA 3 3V DC 310mA 3 5mA 65mA Temperatur...

Page 64: ...ing the product If you need assistance installing or troubleshooting your scanner please contact the JADAK office in your area North America 7279 William Barry Blvd North Syracuse New York 13212 3349...

Page 65: ...ct without charge except for return shipping to JADAK EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR I...

Page 66: ...following pages as well as a brief description of what the parameter choices mean Some commands require further elaboration that can be found in the relevant sections in the guide For example the com...

Page 67: ...depicts a non displayable response Query Goal What is the range of possible values for the Code 128 Max Length Send 128MAXL CR Response 0 55 CR Query Goal What is the default value for the Code 128 M...

Page 68: ...L Max Code 39 Symbol Length 48 48 48 0 48 C39MINL Min Code 39 Symbol Length 0 0 0 0 48 C39CONV Convert C39 to C32 Pharmacode 0 0 0 0 1 CBRDEFA Default Codabar Parameters N A N A N A N A CBRENAB Enable...

Page 69: ...ymbol Length BEEPBEL 0 to 1 0 Enable Beep on BEL BEEPPWR 0 to 1 0 Enable power up beep BEPGDRD 0 to 1 1 Enable good read beeper BEPLEVL 0 to 3 3 Beeper level 0 Off 1 Low 2 Medium 3 High BEPTIME 0 to 2...

Page 70: ...oad a firmware moc file via XModem E13DEFA Default EAN13 Parameters E13ENAB 0 to 1 1 Enable Decoding EAN13 EA8DEFA Default EAN8 Parameters EA8ENAB 0 to 1 1 Enable EAN8 Decoding EXP_MAX 13400 to 150000...

Page 71: ...to 48 48 Max MSI Symbol Length MSIMINL 4 to 48 4 Min MSI Symbol Length MULTSYM 0 to 1 0 Multiple Symbol mode NO_READ 0 to 1 0 Enable no read output NORDMSG Message output by the scanner for NO READ PD...

Page 72: ...00 9900 Trigger Time Out in milliseconds UE1ENAB 0 to 1 0 Enable UPC E1 Decoding UPADEFA Default UPC A parameters UPAENAB 0 to 1 1 Enable UPC A Decoding UPAXMIT 0 to 1 1 Transmit UPC A Enable Check di...

Page 73: ...JADAK JE 238 User s Manual Page 72 Appendix B Programming Chart After you re done with setting the value with the barcodes above finish with scanning SAVE...

Page 74: ...n code 1 in first symbol character position 2 Function code 1 in second symbol character position Example A Code EAN 128 bar code with Function 1 character FNC1 in the first position AIMID is transmit...

Page 75: ...d and stripped check digit Example An I 2 of 5 bar code without check digit 4123 is transmitted as I04123 PDF417 Macro PDF417 Micro PDF417 L 0 Reader set to conform to protocol defined in 1994 PDF417...

Page 76: ...ed FNC1 implied in second position Discrete 2 of 5 IATA 2 of 5 S 0 No options specified at this time Always transmit 0 Example A D 2 of 5 bar code 4123 is transmitted as S04123 Maxicode U 0 Symbol in...

Page 77: ...104 68 h 9 09 HT 41 29 73 49 I 105 69 i 10 0A LF 42 2A 74 4A J 106 6A j 11 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n...

Page 78: ...8A 170 AA 202 CA 234 EA 139 8B 171 AB 203 CB 235 EB 140 8C 172 AC 204 CC 236 EC 141 8D 173 AD 205 CD 237 ED 142 8E 174 AE 206 CE 238 EE 143 8F 175 AF 207 CF 239 EF 144 90 176 B0 208 D0 240 F0 145 91...

Page 79: ...JADAK JE 238 User s Manual Page 78 Appendix E Sample Bar Codes UPC A Codabar Code 128 Code 39 Code 93 Interleaved 2 of 5 PDF 417 Composite Code MicroPDF Aztec Data Matrix QR Code MaxiCode...

Page 80: ...ry Blvd Parkring 57 59 North Syracuse NY 13212 85748 Garching bei M nchen United States of America Germany Phone 1 315 701 0678 Phone 49 0 89 31 707 0 Fax 1 315 701 0679 Fax 49 0 89 31 707 222 e mail...

Reviews: