Manual, F/T Sensor, Axia90
Document #9620-05-B-Axia90-03
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
B-18
3.5 Remove the Sensor
Tools required:
3 mm hex key
1. Turn off all energized circuits, for example: electrical.
2. Remove the cable from the sensor.
3.
Supporting the customer tooling, remove the customer supplied screws that attach the customer
tooling to the sensor.
4. Supporting the sensor, use a 3 mm hex key to remove the (6) M4 socket head cap screws that secure to
the sensor to the mounting interface plate or surface.
5.
Remove the sensor