Receiving and Unpacking

 

 

Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation 
immediately concerning any discrepancy. Inspect equipment to detect any damage that may have 
occurred during shipment. In the event of damage, any claim for loss must be filed immediately with 
the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee 
to contact NovaLynx Corporation for instructions. 

 

Returns

 

 

If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 
p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned 
equipment a description of the problem and the name, address, and daytime phone number of the 
sender. Carefully pack the equipment to prevent damage or additional damage during the return 
shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing 
facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service 
and obtain assistance with the packaging. Please write the RA# on the outside of the box. 

 

Warranty

 

 

NovaLynx Corporation warrants that its products are free from defects in material and workmanship 
under normal use and service for a period of one year from the date of shipment from the factory. 
NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) 
replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx 
Corporation's liability exceed product's original purchase price. This warranty does not apply to any 
equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been 
subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of 
all warranties of fitness and in lieu of the warranty of merchantability. 

 

Address

 

 

NovaLynx Corporation 
431 Crown Point Circle, Suite 120 
Grass Valley, CA 95945-9531 USA 
Phone: (530) 823-7185 
Email: [email protected] 
Website: www.novalynx.com

 

 

Copyright © 1988-2021 by NovaLynx Corporation

 

 

Summary of Contents for 200-WS-01 Series

Page 1: ...DOC 200 WS 01 UM 20210413 200 WS 01x User Manual WeatherPort Wind Speed Sensors Wind Run Sensors Phone 530 823 7185 Email nova novalynx com Website www novalynx com...

Page 2: ...items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging Please write the RA on the outside of...

Page 3: ...ARD 4 2 INTRODUCTION 4 3 PRECAUTIONS 4 4 SPECIFICATIONS 5 5 MODEL NUMBERS AND FEATURES 5 5 1 Wind Run Sensors 5 5 2 Wind Speed Sensors 6 6 SITE SELECTION 6 7 MOUNTING OPTIONS 7 8 INSTALLATION 8 9 MAIN...

Page 4: ...ached to the side of the sensor as shown in the photo or it exits the base Be aware that if the cable exits the base it must be threaded through the supporting mast Cable Side Exit The 200 WS 01 is a...

Page 5: ...12 m 2 conductor 24 AWG shielded tinned leads Except Model 200 WS 01C which has 1 0 3 m hookup wire 1 07 inch diameter by 0 82 inch socket 27 mm dia x 21 mm Note Standard 3 4 IPS pipe is 1 05 o d and...

Page 6: ...threshold due to a characteristic of the Teflon bearing 6 SITE SELECTION WARNING Avoid overhead power lines whenever possible If there are overhead power lines use extreme care to prevent contact wit...

Page 7: ...ious lengths Swaged mast segments can be fitted together to obtain the overall height needed The swaged end is the correct diameter for mounting 200 WS 01x sensors 1 07 1 25 SWAGED ALUMINUM MAST 3 75...

Page 8: ...ies that are resistant to ultra violet radiation and place them at two foot intervals Leave a drip loop of cable below the entry point to the equipment enclosure to help keep moisture out Turn off pow...

Page 9: ...ripod These tests can help determine whether the sensor needs repair or adjustment Set the ohm meter to a low resistance range and touch its leads together to check for zero ohms If it is an analog me...

Page 10: ...NovaLynx Corporation_____________________________________________________________________________________________________________________ 200 WS 01 Page 10 April 2021 APPENDIX A TRIPOD DIMENSIONS...

Reviews: