CHAPTER 7
OPERATIONAL VISUAL INDICATORS
7.1
G203V Indicators
POWER LED
–
The GREEN POWER indicator is lit whenever the G203V has power supply voltage
applied.
FULL POWER LED
–
The YELLOW FULL POWER LED indicator is lit when the motor is turning fast
enough to generate maximum possible mechanical power. Power is torque times RPM and
power output reaches its maximum value when this indicator is lit. Use this indicator to verify
your motor is optimally geared to the load.
ERROR LED
–
The RED ERROR is lit when:
•
During power on reset for 1 second when power is first applied to G203V.
•
While the disable input is active.
•
When there is a short circuit on any motor output. Momentarily activate the
DISABLE input to reset.
•
During over temperature shutdown. The LED automatically resets when the drive
temperature drops.
7.2
Break out Board Indicators (C11G)
•
POWER LED
–
the red power indicator is lit whenever the break out board has power
supply voltage applied.
•
OUTPUT STATUS
–
this LED indicates if the outputs are enabled.
•
Status LEDS
on all inputs and outputs connection
–
you can see all your signals when the
power supply is applied.
•
In all cases the EN pin
must r5vdc in order to enable the inputs. You can
hardwire the EN pin with +5vdc if you do not need to install an external enable switch. If
your E-stop works as NC (normally closed) with a +5vdc signal, you can also send this
signal to the EN. That way your system would have to wait for the control software to
stop.