Wire Color
Start Location
End Location
Function
Blue
DB15, J2-1
Board Ac relay
AC relay
Blue
DB15, J2-2
Board AC relay
AC relay
Orange
DB15, j2-3
Board DC relay NO
Mech. relay N.O
Yellow
DB15, J2-4
Board Analog 0-10
V
Spindle sheet
White
DB15, J2-5
Board 10
Emergency stop
White
DB15, J2-6
Board 11
X,Y,Z axis limit switches
White
DB15, J2-7
Board 12
AUX 1 input
White
DB15, J2-8
Board 13
Aux 2 input
White
DB15, J2-9
Molex, J5 -4
Group 2 Select
Orange
DB15, J2-10
Board DC relay
COM
Mech. Relay Com
Green
DB15, J2-11
Board Analog GND
Analog GND
Blue
DB15, J2-12
Board IN 12 VDC
Group 2 select (12VDC)
Blue
DB15, J2-13
Molex, J5-5
Neg. 12 VDC
Green
DB15, J2-14
Board In GND
Limit Switches COM
Blue
DB15, J2-15
Board IN +12 VDC
12 VDC
Table 6.2: Electrical Connection
Wire Color
Start Location
End Location
Function
Blue
Molex J3-1
Board AC relay
Coolant Pump
Blue
Molex J3-2
Board AC relay
Coolant Pump
Green
Molex J4-1
Terminal Board
Driver ground
Green
Terminal Board
Driver X, pin 1
Driver Ground
Green
Terminal Board
Driver Y, pin 1
Driver ground
Green
Terminal Board
Driver Z, pin 1
Driver ground
Green
Terminal Board
Driver A, pin1
Driver ground
Blue
Fuse holder 1
Driver X, pin 2
X Axis power
Blue
Fuse holder 2
Driver Y, pin 2
Y Axis power
Blue
Fuse Holder 3
Driver Z, pin 2
Z Axis power
Blue
Fuse Holder 4
Driver A, pin 2
A Axis power
Blue
Molex J4-2
Fuse holder 1
X axis high power
Blue
Molex J4-3
Fuse holder 2
Y axis high power
Blue
Molex J4-4
Fuse Holder 3
Z axis high power
Blue
Molex J4-5
Fuse Holder 4
A axis high power
Green
Molex J5-1
Board power ground Low voltage ground
Blue
Molex J5-2
Board power 12V
12 volts DC
Red
Molex J5-3
Board power 5 V
5 volts DC
Blue
Molex J5-4
DB 15, J2-9
Group 2 select
Blue
Molex J5-5
DB15, J2-13
Neg. 12VDC
Table 6.3: J4 & J5 Electrical Connection