background image

                  

 

VELA 440BSW 

 
          USER MANUAL 

20R 440W BSW

 

                  

 

 
 
 
 
 
 

Summary of Contents for VELA 440BSW

Page 1: ...VELA 440BSW USER MANUAL 20R 440W BSW ...

Page 2: ...n 3 1 Control Panel 4 2 Light Source 5 How to Set the Unit 5 1 Main Function 5 2 Home Position Adjustment 5 3 Error Information 6 Control by Universal DMX Controller 6 1 Connection 6 2 Address Setting 6 3 DMX 512 Configuration 7 Troubleshooting 8 Maintenance and Cleaning ...

Page 3: ...uirements of the unit o earth in order to avoid electric shock 40 up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective and it will decrease gradually within 15 minutes hazard nit s surface temperature may reach up to 85 DO NOT touch the housing bare handed during its operation and allow about 15 minutes for cooling the unit down befor...

Page 4: ...ple can lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed ransporting it again Cautions moisture it is damaged deformed or life expired 2 Technical Specifications Power supply AC 100 240V 50 60Hz Power Consumption 600W Fuse T 10A ...

Page 5: ...g protection Dimmer Shutter Blackout 0 100 smooth dimming independent shutter and various strobe effect Color wheel Color wheel 3 color wheels with 5 color plus white CMY Rainbow effect in both directions Gobo wheel Gobo Wheel 1 Fixed gobo wheel with 18 gobos plus open 1 Rotating gobo wheel with 7 gobos plus open Prism Prism 1 16 facet prisms rotating in both directions Prism 2 8prism rotating in ...

Page 6: ...panel diagram left area is TFT Displayer support touch and right area is encoder button both of touch and coder button can operate light and setting Display operation just like Android operation system touch the item will set or modify setting Note Prevent damage the touch or TFT displayer cannot use sharp objects chick displayer Operation Operate light with touch or encoder button ...

Page 7: ...alue Can quickly modify value via pull the slider to the desired position or click the button of up or down whit finger on the right side to set the exact desired value another way is roll encoder on the right hand side of panel Apply value When Value had been modified then press the bottom of apply in the left corner to apply to the light but hav t saved Save Value Any time click on the lower rig...

Page 8: ...parameter menu In main menu chick 1 6 function button into corresponding parameter menu In sub menu page chick main item on the left side of displayer can shift to corresponding sub menu page quickly Set DMX Address Click and select the ADDR can enter the page of DMX address setting range from 1 to 512 the address code shouldn t be not greater than 512 channels quantity otherwise the light will no...

Page 9: ...Address 26 1 27 53 79 6 3 DMX 512 Configuration Please refer to below configurations to control the fixtures Attentions 1 The unit will maintain the last condition until reset if you cut off the DMX signal 2 For the channel Function keep the value for about 5 seconds then the corresponding function will take into effect 26Channels Mode 1 CHANNEL1 Designation Value FUNCTION CH1 PAN 0 255 Pan 0 540 ...

Page 10: ... 149 169 Colour 1 170 191 Colour 2 192 212 Colour 3 213 233 Colour 4 234 255 Colour 5 CH13 GOBO1 000 003 Open 004 009 GOBO 1 010 015 GOBO 2 CHANNEL1 Designation Value FUNCTION CH13 Static GOBO 16 21 Gobo3 22 27 Gobo4 28 33 Gobo5 34 39 Gobo6 40 45 Gobo7 46 51 Gobo8 52 57 Gobo9 58 63 Gobo10 64 69 Gobo11 70 75 Gobo12 76 81 Gobo13 82 87 Gobo14 88 95 Gobo1 shaking slow to fast 96 103 Gobo2 shaking slow...

Page 11: ...w to fast 1 106 155 shaking slow to fast 2 156 205 shaking slow to fast 3 206 255 Continuous animation disk counter clockwise rotation at linearly variable speed from slow to fast CH15 Rotating GOBO 0 010 Empty position 011 020 GOBO1 021 030 GOBO2 031 040 GOBO3 041 050 GOBO4 051 060 GOBO5 CHANNEL1 Designation Value FUNCTION CH15 61 70 Gobo6 71 80 Gobo7 81 90 Gobo1 shaking slow to fast 91 100 Gobo2...

Page 12: ...rom fast 191 192 Stop rotation 193 255 Continuous gobo wheel counter clockwise rotation at linearly variable speed from slow CH19 Prism amplification 000 255 linearly moves from narrow to wide be CH20 Rainbow 000 127 Empty position 128 255 Rainbow CH21 Frost 000 127 Empty position 125 255 Frost moves linearly into the light beam CH22 Zoom 000 255 Zoom linearly moves from narrow to wide beam CH23 F...

Page 13: ...ry to use another DMX controller 5 Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition D The lamp is cutting out intermittentl...

Page 14: ... the cable or cable joints immediately once they ve turned yellow B Do maintain the fixtures every two months and make sure that all the screws and terminals have been locked firmly to make sure the normal performance of the fixtures Negligence of maintenance would cause malfunction of the fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out peri...

Reviews: